Failure of LCP Condylar Plate Fixation in the Distal Part of the Femur: A Report of Six Cases
- 1 April 2006
- journal article
- case report
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 88 (4) , 846-853
Abstract
The treatment of comminuted, intra-articular distal femoral fractures (Orthopaedic Trauma Association [OTA] classification1 33-C3) is challenging. Many of these injuries are the result of high-energy trauma, which generates severe soft-tissue damage and articular and metaphyseal comminution. Bone loss resulting from open fracture and poor bone quality may decrease the stability of fixation. Traditional devices for internal fixation have included the 95° condylar blade-plate, the dynamic condylar screw with a 95° side-plate, and intramedullary nails. However, coronal fractures or extensive distal comminution may preclude the use of these devices. In such cases, a lateral buttress or neutralization plate may be used. The condylar buttress plate was the first implant designed to serve this function. Unfortunately, when this device is applied in the presence of medial comminution or bone loss, failure of fixation and varus collapse may eventually result2,3. Recent advances in technology for the treatment of distal femoral fractures include the Less Invasive Stabilization System (LISS; Synthes, Paoli, Pennsylvania) and the Locking Compression Plate (LCP) condylar plate (Synthes)4-15. Each of these implants offers multiple points of fixed-angle contact between the plate and screws in the distal part of the femur, theoretically reducing the tendency for varus collapse that is seen with traditional lateral plates. The LISS differs from the LCP condylar plate in composition, shape, and placement. Early clinical studies of the LISS have demonstrated a high frequency of fracture union with low rates of malalignment7-9,15. Few cases of failure of the LISS have been reported11,12,16. To our knowledge, there have been no published studies focusing specifically on the LCP condylar plate and no reported cases of failure of this implant in the distal part of the femur. The purposes …Keywords
This publication has 13 references indexed in Scilit:
- Biomechanics of Locked Plates and ScrewsJournal of Orthopaedic Trauma, 2004
- Early Results of the Less Invasive Stabilization System for Mechanically Unstable Fractures of the Distal Femur (AO/OTA Types A2, A3, C2, and C3)Journal of Orthopaedic Trauma, 2004
- Treatment of Distal Femur Fractures Using the Less Invasive Stabilization SystemJournal of Orthopaedic Trauma, 2004
- Failure of Less Invasive Stabilization System Plates in the Distal FemurJournal of Orthopaedic Trauma, 2004
- The development of the distal femur Less Invasive Stabilization System (LISS)Injury, 2001
- Minimally invasive fracture stabilization of distal femoral fractures with the LISS: A prospective multicenter study results of a clinical study with special emphasis on difficult casesInjury, 2001
- Biomechanical Evaluation of the Less Invasive Stabilization System for the Internal Fixation of Distal Femur FracturesJournal of Orthopaedic Trauma, 2001
- The Results of Open Reduction and Internal Fixation of Distal Femur Fractures Using a Biologic (Indirect) Reduction TechniqueJournal of Orthopaedic Trauma, 1996
- Pelvic Ring Disruptions1990
- Problems in the Management of Type III (Severe) Open Fractures1984