Hardware-related infections after deep brain stimulation surgery: review of incidence, severity and management in 212 single-center procedures in the first year after implantation
- 27 August 2011
- journal article
- review article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 153 (12) , 2337-2341
Abstract
Device-related infection is a common occurrence after deep brain stimulation (DBS) surgery, and may result in additional interventions and a loss of efficacy of therapy. This retrospective review aimed to evaluate the incidence, severity and management of device-related infections in 212 DBS procedures performed in our institute. Data on 106 patients, in whom 212 DBS procedures were performed between 2001 and 2011 at our institute by a single neurosurgeon (M.P.), were reviewed to assess the incidence, severity, management and clinical characteristics of infections in the first year after the implantation of a DBS system. Infections occurred in 8.5% of patients and 4.2% of procedures. Of the nine infections, eight involved the neurostimulator and extensions, and one the whole system. The infections occurred 30.7 days after implantation: 7 within 30 days and 2 within 6 months. Infected and uninfected patients were comparable in terms of age, sex, indication for DBS implantation and neurostimulator location. In eight cases, the system components involved were removed and re-implanted after 3 months, while in one case the complete hardware was removed and not re-implanted. The overall incidence of postoperative infections after DBS system implantation was 4.2%; this rate decreased over time. All infections required further surgery. Correct and timely management of partial infections may result in successful salvage of part of the system.Keywords
This publication has 12 references indexed in Scilit:
- Infections and Hardware Salvage after Deep Brain Stimulation Surgery: A Single-Center Study and Review of the LiteratureStereotactic and Functional Neurosurgery, 2010
- Significant reduction in stereotactic and functional neurosurgical hardware infection after local neomycin/polymyxin applicationJournal of Neurosurgery, 2009
- DEEP BRAIN STIMULATOR HARDWARE-RELATED INFECTIONSNeurosurgery, 2008
- Complications in subthalamic nucleus stimulation surgery for treatment of Parkinson’s disease. Review of 272 proceduresActa Neurochirurgica, 2007
- Short-term and long-term safety of deep brain stimulation in the treatment of movement disordersJournal of Neurosurgery, 2007
- Operative and hardware complications of deep brain stimulation for movement disordersBritish Journal Of Neurosurgery, 2006
- Hardware-related complications of deep brain stimulation: a ten year experienceActa Neurochirurgica, 2005
- Reducing Hardware-Related Complications of Deep Brain StimulationCanadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques, 2005
- Surgical and hardware complications of subthalamic stimulationNeurology, 2004
- Hardware-Related Complications after Placement of Thalamic Deep Brain Stimulator SystemsStereotactic and Functional Neurosurgery, 2002