Harnessing the Manifold Structure of Cardiomechanical Signals for Physiological Monitoring During Hemorrhage
- 4 August 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 68 (6) , 1759-1767
Abstract
Objective: Local oscillation of the chest wall in response to events during the cardiac cycle may be captured using a sensing modality called seismocardiography (SCG), which is commonly used to infer cardiac time intervals (CTIs) such as the pre-ejection period (PEP). An important factor impeding the ubiquitous application of SCG for cardiac monitoring is that morphological variability of the signals makes consistent inference of CTIs a difficult task in the time-domain. The goal of this work is therefore to enable SCG-based physiological monitoring during trauma-induced hemorrhage using signal dynamics rather than morphological features. Methods: We introduce and explore the observation that SCG signals follow a consistent low-dimensional manifold structure during periods of changing PEP induced in a porcine model of trauma injury. Furthermore, we show that the distance traveled along this manifold correlates strongly to changes in PEP ( $\Delta$ PEP). Results: $\Delta$ PEP estimation during hemorrhage was achieved with a median $R^2$ of 92.5% using a rapid manifold approximation method, comparable to an ISOMAP reference standard, which achieved an $R^2$ of 95.3%. Conclusion: Rapidly approximating the manifold structure of SCG signals allows for physiological inference abstracted from the time-domain, laying the groundwork for robust, morphology-independent processing methods. Significance: Ultimately, this work represents an important advancement in SCG processing, enabling future clinical tools for trauma injury management.Keywords
Funding Information
- Office of Naval Research (N000141812579)
- NSF (CCF-1409422)
- NSF CAREER (CCF-1350954)
This publication has 31 references indexed in Scilit:
- Validation of lower body negative pressure as an experimental model of hemorrhageJournal of Applied Physiology, 2014
- Precordial Vibrations Provide Noninvasive Detection of Early-Stage HemorrhageShock, 2014
- Wearable seismocardiography: Towards a beat-by-beat assessment of cardiac mechanics in ambulant subjectsAutonomic Neuroscience, 2013
- Change in pulse transit time and pre-ejection period during head-up tilt-induced progressive central hypovolaemiaJournal of Clinical Monitoring and Computing, 2007
- Techniques Used for the Determination of Blood VolumeThe American Journal of the Medical Sciences, 2007
- All-Optical Nanoscale pH MeterNano Letters, 2006
- Impact of Hemorrhage on Trauma Outcome: An Overview of Epidemiology, Clinical Presentations, and Therapeutic ConsiderationsJournal of Trauma: Injury, Infection & Critical Care, 2006
- Noninvasive Doppler-derived myocardial performance index: Correlation with simultaneous measurements of cardiac catheterization measurementsJournal of the American Society of Echocardiography, 1997
- Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testingThe American Journal of Cardiology, 1993
- Pre‐ejection Period: Measuring Beta‐adrenergic Influences Upon the HeartPsychophysiology, 1979