The Accuracy of Lateral Cephalogram for Measuring Alveolar Bone Thickness and Root Diameter on Mandibular Incisors
Open Access
- 14 December 2022
- journal article
- research article
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 3159
Abstract
Background: The objective of the study was to ascertain whether the alveolar bone and root of the mandibular central incisor measured from cephalograms can represent the same measurements of both mandibular central and lateral incisors from CBCT. Methods: A total of 38 sets of CBCT images and cephalograms before treatment were selected for this study. Thicknesses included alveolar bone, cortical bone, and cancellous bone at the labial and lingual sides. Root diameter and total root-bone thickness were also evaluated. The measurements were performed at 3, 6, and 9 mm from the cemento-enamel junction. Heights included labial bone height and lingual bone height. All measurements were performed on cephalograms and CBCT images of the mandibular central incisor (L1CT) and mandibular lateral incisor (L2CT). The data were statistically analyzed using one-way ANOVA and Bonferroni tests (p < 0.01) to compare the cephalograms, L1CT, and L2CT. Results: The cephalograms presented thicker alveolar bone and cortical bone (labial: 0.16–0.31 mm, lingual: 0.14–0.29 mm; p < 0.001) as well as higher alveolar crest (labial: 0.46–0.48 mm, lingual: 0.38–0.39 mm; p < 0.001) than the CBCT images on both the labial and lingual sides, whereas lingual cancellous thicknesses were not significantly different (p = 0.257). The cephalograms presented greater total root-bone thicknesses than L1CT (0.19–0.30 mm; p < 0.001), whereas the cephalograms traced thinner roots than L1CT (0.18–0.23 mm; p < 0.001) and L2CT (0.39–0.59 mm; p < 0.001). Conclusion: Lateral cephalograms cannot represent both mandibular central and lateral incisor dentoalveolar thicknesses, heights, and root diameters the same as CBCT. However, the differences were less than 0.5 mm.Keywords
Funding Information
- Faculty of Dentistry and Prince of Songkla University
This publication has 40 references indexed in Scilit:
- Comparative study between conventional and cone beam CT-synthesized half and total skull cephalogramsDentomaxillofacial Radiology, 2012
- Dehiscence and fenestration in skeletal Class I, II, and III malocclusions assessed with cone-beam computed tomographyThe Angle Orthodontist, 2012
- Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering programin vivoDentomaxillofacial Radiology, 2011
- Assessment of antero-posterior skeletal relationships in adult Korean patients in the natural head position and centric relationThe Korean Journal of Orthodontics, 2010
- Comparison of Clinical, Periapical Radiograph, and Cone‐Beam Volume Tomography Measurement Techniques for Assessing Bone Level Changes Following Regenerative Periodontal TherapyJournal of Periodontology, 2009
- Alveolar bone anatomic profiles as measured from dry skullsJournal of Clinical Periodontology, 1997
- Periodontal status of mandibular incisors following excessive proclination A study in adults with surgically treated mandibular prognathismAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1987
- Expansion and fenestration or dehiscenceAmerican Journal of Orthodontics, 1980
- The reliability of head film measurementsAmerican Journal of Orthodontics, 1971
- Measurement on RadiographsJournal of Dental Research, 1962