Undiluted human whole blood uric acid detection using a graphitized mesoporous carbon modified electrode: a potential tool for clinical point-of-care uric acid diagnosis
- 1 March 2018
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (7) , 1560-1567
Abstract
Direct sensing of uric acid (UA) in an undiluted whole blood sample is reported here taking human whole blood as an analyte and a self-supporting electrolyte. Among various solid electrodes (Pt, Au, GCE, and GCE/Nafion) and carbon nanomaterials (carbon nanofibers, graphene oxide, graphite nanopowder, graphitized mesoporous carbon (GMC), single-walled carbon nanotubes, and multiwalled carbon nanotubes) tested, a GMC-modified glassy carbon electrode, designated as GCE/GMC, showed a remarkable response towards direct electrochemical oxidation of blood uric acid at ∼0.25 V vs. Ag/AgCl, unlike the poor and/or feeble current signals with the other unmodified and modified electrodes. It is plausible that the mesoporous nature of the GMC favours the formation of a blood–GMC bio-corona through internalization and provides straight access to blood-matrixed uric acid. Furthermore, the effects of the scan rate and interference with various biochemicals on the GCE/GMC were analysed. The electrochemical oxidation reaction is found to be diffusion controlled in nature and there is no interference from common biochemicals like ascorbic acid, glucose, tryptophan, H2O2, xanthine, hypoxanthine, cysteine, nitrate, nitrite, and sulfide in blood. Real blood UA sample analysis was demonstrated with comparable UA analysis results from the clinical measurement.Keywords
Funding Information
- Anusandhan National Research Foundation (EMR/2016/002818)
- Council of Scientific and Industrial Research, India (09/844(0037)/2016 EMR-I)
- VIT University
- National Taipei University of Technology
This publication has 23 references indexed in Scilit:
- World Incidence of AKIClinical Journal of the American Society of Nephrology, 2013
- Non-enzymatic disposable test strip for detecting uric acid in whole bloodJournal of Electroanalytical Chemistry, 2009
- Uricase based methods for determination of uric acid in serumMicrochimica Acta, 2008
- Direct Electrochemistry of Uric Acid at Chemically Assembled Carboxylated Single-Walled Carbon Nanotubes Netlike ElectrodeThe Journal of Physical Chemistry B, 2006
- Hereditary renal hypouricemiaMolecular Genetics and Metabolism, 2006
- New electrodes for old: from carbon nanotubes to edge plane pyrolytic graphiteThe Analyst, 2005
- A disposable single-use electrochemical sensor for the detection of uric acid in human whole bloodSensors and Actuators B: Chemical, 2005
- Hyperuricemia induces endothelial dysfunctionKidney International, 2005
- Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sitesChemical Communications, 2004
- Drug-induced Fanconi's syndromeAmerican Journal of Kidney Diseases, 2003