The determination of terbutaline in human plasma by selected ion monitoring of thet-butyldimethylsilyl ether

Authors:

Abstract
A method is described for the quantitative determination of terbutaline in 2 ml human plasma. The drug is extracted from plasma as the terbutaline tetraphenylboron ion pair and determined by gas chromatography mass spectrometry of its t‐butyldimethylsilyl ether. Salbutamol is used as internal standard. Quantification is achieved by selected ion monitoring of the ion m/z 482 derived from t‐butyldimethylsilyl terbutaline and m/z 495 from t‐butyldimethylsilyl salbutamol. The detection limit was estimated to be 250 pg terbutaline ml−1 plasma. The coefficient of variation at the level of 1 ng terbutaline ml−1 was 4.1% (n = 5).