The determination of terbutaline in human plasma by selected ion monitoring of thet-butyldimethylsilyl ether
Authors:
- 1 October 1979
- journal article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 6 (10) , 460-461
Abstract
A method is described for the quantitative determination of terbutaline in 2 ml human plasma. The drug is extracted from plasma as the terbutaline tetraphenylboron ion pair and determined by gas chromatography mass spectrometry of its t‐butyldimethylsilyl ether. Salbutamol is used as internal standard. Quantification is achieved by selected ion monitoring of the ion m/z 482 derived from t‐butyldimethylsilyl terbutaline and m/z 495 from t‐butyldimethylsilyl salbutamol. The detection limit was estimated to be 250 pg terbutaline ml−1 plasma. The coefficient of variation at the level of 1 ng terbutaline ml−1 was 4.1% (n = 5).Keywords
This publication has 3 references indexed in Scilit:
- The analysis of terbutaline in biological fluids by gas chromatography electron impact mass spectrometryJournal of Mass Spectrometry, 1979
- Quantitative analysis of terbutaline in serum and urine at therapeutic levels using gas chromatography—mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1977
- Quantitative determination of salbutamol in plasma, as either its trimethylsilyl ort-butyldimethylsilyl ether, using a stable isotope multiple ion recording techniqueJournal of Mass Spectrometry, 1976