Laryngeal Muscle Activity during Nasal High-Frequency Oscillatory Ventilation in Nonsedated Newborn Lambs
Authors:
- Nathalie SamsonNSNathalie Samson
- Charlène NadeauCNCharlène Nadeau
- Nadia BoudaaNBNadia Boudaa
- Jean-Paul PraudJPJean-Paul Praud
- 31 January 2015
- journal article
- Published by S. Karger AG in Neonatology
- Vol. 107 (3) , 199-205
Abstract
Background: We have previously shown that nasal pressure support ventilation (nPSV) can lead to an active inspiratory laryngeal narrowing in lambs. This, in turn, can limit lung ventilation and divert air into the digestive system, with potentially deleterious consequences. On the other hand, nasal high-frequency oscillatory ventilation (nHFOV) is particularly attractive in newborns, especially since, unlike nPSV, it does not require synchronization with the patient's inspiratory efforts. Objectives: The main aim of the present study was to test the hypothesis that glottal constrictor muscle activity (EMG) does not develop during nHFOV. A secondary objective was to study laryngeal EMG during nHFOV-induced central apneas. Methods: Polysomnographic recordings were performed in 7 nonsedated lambs which were ventilated with increasing levels of nPSV and nHFOV at both 4 and 8 Hz, in random order. States of alertness, diaphragm and glottal muscle EMG, SpO2, and respiratory movements were continuously recorded. Results: While phasic inspiratory glottal constrictor EMG appeared with increasing nPSV levels in 6 out of 7 lambs, it was never observed with nHFOV. In addition, nHFOV at 4 Hz dramatically inhibited central respiratory drive in 4/7 lambs, with 64-100% of recording time spent in central apnea in 3 lambs. No glottal constrictor EMG was observed during these central apneas. Conclusion: nHFOV does not induce glottal constrictor muscle EMG in nonsedated newborn lambs, in contrast to nPSV. This may be an additional advantage of nHFOV relative to nPSV.Keywords
This publication has 21 references indexed in Scilit:
- Noninvasive ventilation and the upper airway: should we pay more attention?Critical Care, 2013
- Nasal High-Frequency Oscillation for Lung Carbon Dioxide Clearance in the NewbornNeonatology, 2012
- Absence of inspiratory laryngeal constrictor muscle activity during nasal neurally adjusted ventilatory assist in newborn lambsJournal of Applied Physiology, 2012
- Nasal intermittent positive pressure ventilation after surfactant treatment for respiratory distress syndrome in preterm infants <30 weeks’ gestation: a randomized, controlled trialJournal of Perinatology, 2012
- Mechanical ventilation in the newborn; a simplified approach Part 2: High‐frequency ventilationJournal of Paediatrics and Child Health, 2010
- Nasal high frequency percussive ventilation versus nasal continuous positive airway pressure in transient tachypnea of the newborn: A pilot randomized controlled trial (NCT00556738)Pediatric Pulmonology, 2010
- Mechanisms of active laryngeal closure during noninvasive intermittent positive pressure ventilation in nonsedated lambsJournal of Applied Physiology, 2008
- Should nasal high‐frequency ventilation be used in preterm infants?Acta Paediatrica, 2008
- Nasal high‐frequency ventilation for premature infantsActa Paediatrica, 2008
- Reflex apnea induced by high-frequency oscillatory ventilation in rabbitsRespiration Physiology, 1991