A calibrated capacitance transducer for the detection of acoustic emission
Authors:
- 1 August 1978
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 11 (11) , 1487-1494
Abstract
The authors describe a capacitance transducer for use as a calibrated detector of energetic acoustic emission events. It is displacement-sensitive with a wide frequency response, and typically has a rise-time of 20 ns. The electrical output of the transducer has been calibrated as a function of displacement, and the device has been tested in a broad-band acoustic emission system. It is envisaged that the transducer could either be used to measure emission transients directly, or act as a reference against which conventional piezoelectric transducers could be compared.Keywords
This publication has 3 references indexed in Scilit:
- Acoustic emission: some applications of Lamb’s problemThe Journal of the Acoustical Society of America, 1975
- Characteristics and mechanisms of acoustic emission from solids under applied stressC R C Critical Reviews in Solid State Sciences, 1973
- Motion of the Surface of a Uniform Elastic Half-Space Produced by a Buried PulseThe Journal of the Acoustical Society of America, 1957