Improvement of the Assessment Method for Fire Resistance of Steel Structures in the Temperature Regime of Fire under Realistic Conditions
Authors:
- 7 August 2020
- journal article
- research article
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1006, 107-116
Abstract
There was researched the influence of fire temperature regimes, obtained by the proposed mathematical models, on the mechanical characteristics of metal structures. As a result, the identified patterns of the influence of the parameters of the premises with fires are shown as the slit coefficient decreases and the fire load density increases, the actual limit of fire resistance begins to decrease, as well as at values of fire load density less than 600 [MJ/m2], there is an area where the occurrence of a boundary state is not observed and Nomograms for determining the limit of fire resistance for steel structures at standard values of critical temperature were constructed and an appropriate method was developed.Keywords
This publication has 5 references indexed in Scilit:
- The research of carrying capacity of reinforced concrete walls under uneven warmingIOP Conference Series: Materials Science and Engineering, 2019
- Experimental study of temperature mode of a fire in a cable tunnelEastern-European Journal of Enterprise Technologies, 2018
- Calculation of Limits of Fire Resistance for Structures with Fire Retardant CoatingMATEC Web of Conferences, 2016
- Elefir‐EN2010
- A simple model for the fire resistance of axially loaded members—comparison with experimental resultsJournal of Constructional Steel Research, 1996