An implantable wireless bidirectional communication microstimulator for neuromuscular stimulation
Authors:
- 12 December 2005
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 52 (12) , 2526-2538
Abstract
This paper presents the integrated circuit design for a wireless bidirectional transmission microstimulator. This implantable device is composed of an internal radio-frequency (RF) front-end circuit, a control circuit, a stimulator, and an on-chip transmitter. A 2-MHz amplitude-shift keying modulated signal, including the power and data necessary for the implantable device, is received, and a stable 3-V dc voltage and digital data will be extracted to further execute neuromuscular stimulation. The current-mode microstimulator can produce a bidirectional output current with 8-bit resolution for stimulation. The maximum stimulation current is 1 mA while the stimulation frequency is from 20 Hz to 2 kHz and the pulsewidth of stimulation current is from 150 to 500 /spl mu/s. Furthermore, the system can acquire the biological sensing signal by means of an on-chip transmitter. Most of the signal processing circuits have been designed with low-power schemes to reduce the power consumption, and the performance is also conformed to the requirements of the microstimulator. All of the circuits except for the RF link are combined in a single chip and implemented in TSMC 0.35-/spl mu/m 2P4M standard CMOS process.Keywords
This publication has 18 references indexed in Scilit:
- High frequency block of selected axons using an implantable microstimulatorJournal of Neuroscience Methods, 2004
- An efficient RF power transfer and bidirectional data transmission to implantable electronic devices2003
- Programmable high-amplitude balanced stimulus current-source for implantable microstimulators2002
- Electrical stimulation for the treatment of bladder dysfunction: Current status and future possibilitiesNeurological Research, 2002
- A neuro-stimulus chip with telemetry unit for retinal prosthetic deviceIEEE Journal of Solid-State Circuits, 2000
- Electronic design of a multichannel programmable implant for neuromuscular electrical stimulationIEEE Transactions on Rehabilitation Engineering, 1999
- Introduction to cochlear implantsIEEE Engineering in Medicine and Biology Magazine, 1999
- A low-voltage, low quiescent current, low drop-out regulatorIEEE Journal of Solid-State Circuits, 1998
- A novel instrumentation amplifier with reduced magnitude and phase errorsIEEE Transactions on Instrumentation and Measurement, 1991
- A discrete/continuous time-domain analysis of a generalized class E amplifierIEEE Transactions on Circuits and Systems, 1990