Abstract
The free induction decay (FID) transversal signal is always employed by a proton precession magnetometer (PPM) to evaluate the time-domain geomagnetic field. Nevertheless, the signal-to-noise ratio (SNR) is an important factor that severely affects the detection accuracy of the magnetic field due to uncontrollable interference sources, including random noise and power frequency noise. In this study, aiming to boost the SNR of the FID transversal signal, a novel filtering algorithm based on a prewhiten (PW) strategy is proposed and the PW filtering was combined with singular value decomposition (SVD) for further noise reduction. This method aims to generate adaptive PW input data before filtering, further decorrelating the noise to reduce the impact of varying noise levels in the received FID signals. The efficiency of the proposed joint filtering framework, dubbed PW-SVD, was evaluated by comparing with two state-of-the-art methods, i.e., SVD and principal component analysis and decomposition, using the same data. The results demonstrated that the proposed PW-SVD method obtained the smallest root mean square error and the highest signal-to-noise ratio improvement among all the compared methods, especially for the strong-noisy scenario, which enhances the environmental adaptability of a PPM.Keywords
Funding Information
- National Natural Science Foundation of China (41904164, 41874212)
- Foundation of National Key R&D Program of China (2018YFC1503702)
- Foundation of Science and Technology on Near-Surface Detection Laboratory (6142414180913)
- Fundamental Research Funds for the Central Universities, China University of Geo-sciences (CUG190628)
This publication has 19 references indexed in Scilit:
- A fusion of principal component analysis and singular value decomposition based multivariate denoising algorithm for free induction decay transversal dataReview of Scientific Instruments, 2019
- A frequency measurement method based on optimal multi-average for increasing proton magnetometer measurement precisionMeasurement, 2019
- Apparatus and method for efficient sampling of critical parameters demonstrated by monitoring an Overhauser geomagnetic sensorReview of Scientific Instruments, 2018
- A New Probabilistic Multi-Hop Broadcast Protocol for Vehicular NetworksIEEE Transactions on Vehicular Technology, 2018
- A Nonlinear Regression Application via Machine Learning Techniques for Geomagnetic Data Reconstruction ProcessingIEEE Transactions on Geoscience and Remote Sensing, 2018
- Laboratory Investigation Into the Formation and Dissociation Process of Gas Hydrate by Low‐Field NMR TechniqueJournal of Geophysical Research: Solid Earth, 2018
- Noise characterization for the FID signal from proton precession magnetometerJournal of Instrumentation, 2017
- A High-Precision Frequency Measurement Algorithm for FID Signal of Proton MagnetometerIEEE Transactions on Instrumentation and Measurement, 2016
- Noise reduction of nuclear magnetic resonance (NMR) transversal data using improved wavelet transform and exponentially weighted moving average (EWMA)Journal of Magnetic Resonance, 2015
- Overhauser magnetometer for the Danish Oersted satelliteIEEE Transactions on Magnetics, 1995