Scanning Electron Microscope Study of Scalers
Authors:
- Charles J. AntoniniCACharles J. Antonini
- John M. BradyJBJohn M. Brady
- Marvin P. LevinMLMarvin P. Levin
- Wilfredo Lara GarciaWGWilfredo Lara Garcia
- 1 January 1977
- journal article
- research article
- Published by Wiley in Journal of Periodontology
- Vol. 48 (1) , 45-48
Abstract
Scanning electron microscopy was used to examine factory-sharpened, dulled, and resharpened scalers. The following observations were made: 1. The factory sharpened scalers exhibited metallic extensions from the lateral surface (wire edges). 2. The machine-resharpened instruments resulted in nonfunctional wire edges from the facial surface. Honing produced an exact meeting of facial and lateral surfaces. 3. Hand sharpening, using an Arkansas stone (grit 500) against the lateral surface away from the cutting edge, effected an exact meeting of the facial and lateral surfaces and no evidence of wire edges. 4. From this study an optimum cutting edge for a scaler is characterized as having a smooth, contiguous meeting of the facial and lateral surfaces free of wire edges. If a wire edge is present, it should be functional.Keywords
This publication has 3 references indexed in Scilit:
- Characterization of fretting fatigue damage by SEM analysisWear, 1973
- Programming for sharp curets and sickle scalersJournal of Dental Education, 1973
- Sharpening Periodontal InstrumentsJournal of Periodontology, 1956