Anatomical evaluation of the groove for the vertebral artery in the axis vertebrae for atlanto-axial transarticular screw fixation technique
Authors:
- 23 June 2000
- journal article
- research article
- Published by Wiley in Clinical Anatomy
- Vol. 13 (4) , 237-243
Abstract
Anatomical measurements were studied on 40 dry axis vertebrae to determine the suitability of the groove for the vertebral artery for atlanto-axial transarticular screw fixation technique. We measured 13 parameters including three angular and 10 linear dimensions related to the groove of the vertebral artery, pedicle, and pars interarticularis and evaluated 80 measurements for each parameter. All measurements were done after placing a Kischner guide wire through the pedicle. We found that differences between measurements on the left and right sides of each vertebra were nonsignificant. In spite of the variability in measurements such as height, width, and median angle of the pedicle, the decline angle for instrumentation, the depth of the groove for the vertebral artery, and the internal height of the pars interarticularis, all of these had good symmetry. However, there were statistically significant differences between the sides in measurements for both the width (P=0.05) and the angle (P<0.02) of the pedicle allowing instrumentation and they did not show good symmetry. The risk of vertebral artery injury was found to be 22.5% per specimen, or 16.25% per screw inserted because the internal height of the pars interarticularis at point of fixation was ≤ 2.1 mm. In addition, we found that the pedicle width allowing instrumentation was not suitable in 12.5% of screws inserted because their values were ≤ 6 mm. When the width of the pedicle for instrumentation and the internal height of the pars interarticularis were both evaluated together, we also found that this technique would be extremely dangerous in 7.5% of specimens. In conclusion, the internal height of the pars interarticularis and the width of the pedicle for instrumentation should be evaluated together in thin CT sections preoperatively, because of the risk of vertebral artery injury in patients upon which atlanto-axial transarticular screw fixation is to be performed. Clin. Anat. 13:237–243, 2000.Keywords
This publication has 17 references indexed in Scilit:
- Posterior C1-C2 Transarticular Screw Fixation for Atlantoaxial ArthrodesisNeurosurgery, 1998
- Posterior atlantoaxial facet screw fixation in rheumatoid arthritisJournal of Neurosurgery, 1998
- Variation of the Groove in the Axis Vertebra for the Vertebral ArteryThe Journal of Bone and Joint Surgery. British volume, 1997
- Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation techniqueJournal of Neurosurgery, 1997
- Arteriovenous fistula as a complication of C1–2 transarticular screw fixationJournal of Neurosurgery, 1996
- A Morphological Study on the V2 Segment of the Vertebral ArteryOkajimas Folia Anatomica Japonica, 1996
- C1-C2 Posterior Cervical FusionNeurosurgery, 1995
- Preoperative Oblique Axial Computed Tomographic Imaging for C1–C2 Transarticular Screw Fixation: Technical NoteNeurosurgery, 1995
- Atlanto-axial fusion with transarticular screw fixationThe Journal of Bone and Joint Surgery. British volume, 1991
- Anatomic and Biomechanical Assessment of Transarticular Screw Fixation for Atlantoaxial InstabilitySpine, 1991