Active and passive magnetic shielding for stray field reduction of an induction heater with axial flux
- 9 September 2005
- journal article
- Published by Institution of Engineering and Technology (IET) in IEE Proceedings - Electric Power Applications
- Vol. 152 (5) , 1359-1364
Abstract
A combined active and passive shield is designed for an industrial axisymmetric induction heater for steel wire. Both the active and the passive shield should reduce the magnetic stray field of the induction heater in a given area, namely the target area. They should have low electromagnetic losses and cause a limited change of the heating induced in the workpiece. The positions as well as the currents of the active shield coils and the position and length of the passive shield are optimised. The numerical models are verified by comparing the results with measurements on the unshielded induction heater. Several passive shields (steel, copper and ferrite) and active shields are studied, resulting in a maximal field reduction of 43 dB.Keywords
This publication has 6 references indexed in Scilit:
- High sensitivity 50 Hz-1 MHz probe for B and dB/dt2003
- Occupational exposures to high frequency electromagnetic fields in the intermediate range ( >300 Hz–10 MHz)Bioelectromagnetics, 2002
- Power frequency magnetic field management using a combination of active and passive shielding technologyIEEE Transactions on Power Delivery, 1998
- Principles in transmission line magnetic field reductionIEEE Transactions on Power Delivery, 1996
- An introduction to simulated evolutionary optimizationIEEE Transactions on Neural Networks, 1994