The Changes in Pulse Pressure Variation or Stroke Volume Variation After a “Tidal Volume Challenge” Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation*
- 1 March 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 45 (3) , 415-421
Abstract
Objectives: Stroke volume variation and pulse pressure variation do not reliably predict fluid responsiveness during low tidal volume ventilation. We hypothesized that with transient increase in tidal volume from 6 to 8 mL/kg predicted body weight, that is, “tidal volume challenge,” the changes in pulse pressure variation and stroke volume variation will predict fluid responsiveness. Design: Prospective, single-arm study. Setting: Medical-surgical ICU in a university hospital. Patients: Adult patients with acute circulatory failure, having continuous cardiac output monitoring, and receiving controlled low tidal volume ventilation. Interventions: The pulse pressure variation, stroke volume variation, and cardiac index were recorded at tidal volume 6 mL/kg predicted body weight and 1 minute after the “tidal volume challenge.” The tidal volume was reduced back to 6 mL/kg predicted body weight, and a fluid bolus was given to identify fluid responders (increase in cardiac index > 15%). The end-expiratory occlusion test was performed at tidal volumes 6 and 8 mL/kg predicted body weight and after reducing tidal volume back to 6 mL/kg predicted body weight. Results: Thirty measurements were obtained in 20 patients. The absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight predicted fluid responsiveness with areas under the receiver operating characteristic curves (with 95% CIs) being 0.99 (0.98–1.00) and 0.97 (0.92–1.00), respectively. The best cutoff values of the absolute change in pulse pressure variation and stroke volume variation after increasing tidal volume from 6 to 8 mL/kg predicted body weight were 3.5% and 2.5%, respectively. The pulse pressure variation, stroke volume variation, central venous pressure, and end-expiratory occlusion test obtained during tidal volume 6 mL/kg predicted body weight did not predict fluid responsiveness. Conclusions: The changes in pulse pressure variation or stroke volume variation obtained by transiently increasing tidal volume (tidal volume challenge) are superior to pulse pressure variation and stroke volume variation in predicting fluid responsiveness during low tidal volume ventilation.Keywords
This publication has 27 references indexed in Scilit:
- Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance*Critical Care Medicine, 2012
- Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature*Critical Care Medicine, 2009
- Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patientsCritical Care Medicine, 2009
- Can one predict fluid responsiveness in spontaneously breathing patients?Intensive Care Medicine, 2007
- Comparison of Two Fluid-Management Strategies in Acute Lung InjuryThe New England journal of medicine, 2006
- The Influence of Tidal Volume on the Dynamic Variables of Fluid Responsiveness in Critically Ill PatientsAnesthesia & Analgesia, 2006
- Pulse pressure variations to predict fluid responsiveness: influence of tidal volumeIntensive Care Medicine, 2005
- Using ventilation-induced aortic pressure and flow variation to diagnose preload responsivenessIntensive Care Medicine, 2004
- Relation between Respiratory Changes in Arterial Pulse Pressure and Fluid Responsiveness in Septic Patients with Acute Circulatory FailureAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeThe New England journal of medicine, 2000