Atraumatic dislocation of a modern rotating hinge total-knee prosthesis. A rare but devastating complication
- 18 May 2023
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 117 (1) , 103991
Abstract
The number of total knee arthroplasties (TKA) is rising in many countries along with the numbers of the revision TKA. Rotating hinge knee (RHK) implants have a fundamental role in the revision TKA and their design has evolved during the last years becoming appealing to many surgeons worldwide. They are mainly used in cases where large bone defects and severe soft tissue imbalance exist. However, despite their recent advancements, they are still associated with high complication rates such as infection, periprosthetic fractures and insufficiency of the extensor apparatus. An uncommon complication of the latest rotating hinge implants is their mechanical component failure. Here we present a rare case of such a devastating complication where a modern RHK prosthesis dislocated without a preceding traumatic event, a review of the corresponding literature and a potential cause for the failure of the mechanism. Moreover, insight on key aspects that need to be addressed is provided, like intrinsic and extrinsic factors which play a crucial role and shouldn't be overlooked for a successful outcome.Keywords
This publication has 8 references indexed in Scilit:
- Outcomes of the rotating hinge knee in revision total knee arthroplasty with a median follow-up of 6.2 yearsBMC Musculoskeletal Disorders, 2021
- The role of rotating hinge implants in revision total knee arthroplastyEFORT Open Reviews, 2019
- Rotating Hinge Implants for Complex Primary and Revision Total Knee ArthroplastyThe Journal of Arthroplasty, 2018
- Rotating hinge prosthesis for complex revision total knee arthroplasty: A review of the literatureJournal of Clinical Orthopaedics and Trauma, 2018
- Case Report: Failure of Rotating-hinge Total Knee Prosthesis by Disengagement of the Hinge-post ExtensionClinical Orthopaedics and Related Research, 2012
- Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literatureInternational Orthopaedics, 2011
- Five Cases of Failure of the Tibial Polyethylene Insert Locking Mechanism in One Design of Constrained Knee ArthroplastyThe Journal of Arthroplasty, 2011
- DISLOCATION OF ROTATING HINGE KNEE PROSTHESESJournal of Bone and Joint Surgery, 2005