Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantation
Authors:
- Raciha Beril KucumenRKRaciha Beril Kucumen
- Nursal Melda YenerelNYNursal Melda Yenerel
- Ebru GorgunEGEbru Gorgun
- Destan Nil KulacogluDKDestan Nil Kulacoglu
- Banu OncelBOBanu Oncel
- Maryo Cenk KohenMKMaryo Cenk Kohen
- Murat Levent AlimgilMAMurat Levent Alimgil
- 1 December 2008
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (12) , 2096-2098
Abstract
To evaluate corneal viscoelastic and intraocular pressure (IOP) changes measured by an ocular response analyzer (ORA) after phacoemulsification and intraocular lens (IOL) implantation. Yeditepe University Department of Ophthalmology, Istanbul, Turkey. Fifty-one eyes scheduled for cataract surgery were included in the study. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc), and Goldmann-correlated IOP (IOPg) were measured by ORA preoperatively and 1 week and 1 and 3 months postoperatively. Central corneal thickness (CCT) was measured using the ORA's integrated handheld ultrasonic pachymeter. The mean preoperative CCT (537 microm+/-46 [SD]) did not change significantly by the end of 1 month postoperatively. The mean preoperative IOPcc (17.2+/-3.0 mm Hg) decreased significantly by 3 months postoperatively (15.2+/-3.7 mm Hg) (P= .018). The mean CH decreased from 10.36+/-1.48 mm Hg preoperatively to 9.64+/-1.26 mm Hg at 1 week (P= .028); it increased to preoperative values at the end of 1 month (10.20+/-1.70) and 3 months (10.74+/-1.54) (P>.05). The mean CRF decreased from 10.94+/-2.54 mm Hg preoperatively to 9.99+/-1.77 at 1 week (P= .026); it increased to preoperative values at 1 month (10.26+/-1.59) and 3 months (10.35+/-1.46) (P>.05). Although CH and the CRF decreased in the early postoperative period, the parameters increased and reached preoperative values by 3 months postoperatively, showing that corneal biomechanical properties are influenced by phacoemulsification and IOL implantation.Keywords
This publication has 10 references indexed in Scilit:
- Corneal hysteresis using the Reichert ocular response analyser: findings pre‐ and post‐LASIK and LASEKActa Ophthalmologica, 2008
- Changes in Corneal Hysteresis After Clear Corneal Cataract SurgeryAmerican Journal of Ophthalmology, 2007
- Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyesJournal of Cataract & Refractive Surgery, 2007
- Changes in Corneal Biomechanics and Intraocular Pressure Following LASIK Using Static, Dynamic, and Noncontact TonometryAmerican Journal of Ophthalmology, 2007
- Evaluation of the Influence of Corneal Biomechanical Properties on Intraocular Pressure Measurements Using the Ocular Response AnalyzerJournal of Glaucoma, 2006
- Central Corneal Thickness and Corneal Hysteresis Associated With Glaucoma DamageAmerican Journal of Ophthalmology, 2006
- Measuring intraocular pressure-adjustments for corneal thickness and new technologiesCurrent Opinion in Ophthalmology, 2006
- Analyse der optisch wirksamen Parameter nach Kataraktoperation mit FaltlinsenimplantationDer Ophthalmologe, 2005
- Determining in vivo biomechanical properties of the cornea with an ocular response analyzerJournal of Cataract & Refractive Surgery, 2005
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005