CT Angiographic Measurement of the Carotid Artery: Optimizing Visualization by Manipulating Window and Level Settings and Contrast Material Attenuation
Authors:
- Kenneth D. HopperKHKenneth D. Hopper
- David T. MaugerDMDavid T. Mauger
- Kimberly A. AddisKAKimberly A. Addis
- 1 November 2000
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 217 (2) , 494-500
Abstract
To evaluate a broad range of window and level settings for various contrast material attenuation coefficients and degrees of vascular stenosis to obtain the most accurate computed tomographic (CT) angiographic measurements. A total of 25, 480 measurements were made transversely (perpendicular to the lumen) and by means of maximum intensity projection (MIP) in a phantom with stenoses of 0%-100%, contrast material with attenuation coefficients of 150-350 HU, and 14 window and 13 level settings. Edge definition was also evaluated. There was an inherent relationship between the contrast material attenuation coefficient and the optimal window and level settings in the measurement of stenoses at both transverse and MIP CT angiography. This relationship between the contrast material attenuation coefficient D: and the optimal settings for window W: and level L: was represented by the following simple equations: W:/D: = [-2 x (L:/D:)] + 1.3, where -0.2 < L:/D: < 0.5, and W:/D: = [3.3 x (L:/D:)] - 1.3, where 0.5 < L:/D: < 1.0. With a vascular contrast material attenuation coefficient of 250-350 HU, the best transverse and MIP display settings for the window and level were 96 and 150 HU, respectively. The use of optimized window and level settings at CT angiography reduces measurement variability.Keywords
This publication has 16 references indexed in Scilit:
- Assessment of Renal Artery Stenosis with CT Angiography: Usefulness of Multiplanar Reformation, Quantitative Stenosis Measurements, and Densitometric Analysis of Renal Parenchymal Enhancement as Adjuncts to MIP Film ReadingJournal of Computer Assisted Tomography, 1998
- Measurement of the aorta and its branches with helical CT.Radiology, 1998
- Renal artery stenosis: detection and quantification with spiral CT angiography versus optimized digital subtraction angiography.Radiology, 1997
- Helical CT angiography compared with arteriography in the detection of renal artery stenosis.American Journal of Roentgenology, 1996
- Carotid artery stenosis: a prospective comparison of CT angiography and conventional angiography.American Journal of Roentgenology, 1994
- Spiral CT of renal artery stenosis: comparison of three-dimensional rendering techniques.Radiology, 1994
- CT angiography: application to the evaluation of carotid artery stenosis.Radiology, 1993
- Diagnosis of carotid artery disease: preliminary experience with maximum-intensity-projection spiral CT angiography.American Journal of Roentgenology, 1993
- Three-dimensional spiral CT angiography of the abdomen: initial clinical experience.Radiology, 1993
- CT angiography with spiral CT and maximum intensity projection.Radiology, 1992