Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT)
Open Access
- 21 October 2011
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 6 (1) , 140
Abstract
Purpose: To analyze the differences between the intensity-modulated radiotherapy (IMRT), single/partial-arc volumetric modulated arc therapy (SA/PA-VMAT) techniques in treatment planning for locally advanced lung cancer. Materials and methods: 12 patients were retrospectively studied. In each patient's case, several parameters were analyzed based on the dose-volume histograms (DVH) of the IMRT, SA/PA-VMAT plans respectively. Also, each plan was delivered to a phantom for time comparison. Results: The SA-VMAT plans showed the superior target dose coverage, although the minimum/mean/maximum doses to the target were similar. For the total and contralateral lungs, the higher V5/10, lower V20/30 and mean lung dose (MLD) were observed in the SA/PA-VMAT plans (p < 0.05, respectively). The PA-VMAT technique improves the dose sparing (V20, V30 and MLD) of the controlateral lung more notably, comparing to those parameters of the IMRT and SA-VMAT plans respectively. The delivered monitor units (MUs) and treatment times were reduced significantly with VMAT plans, especially PA-VMAT plans (for MUs: mean 458.3 vs. 439.2 vs. 435.7 MUs, p < 0.05 and for treatment time: mean 13.7 vs. 10.6 vs. 6.4 minutes, p < 0.01). Conclusions: The SA-VMAT technique achieves highly conformal dose distribution to the target. Comparing to the IMRT plans, the higher V5/10, lower V20/30 and MLD were observed in the total and contralateral lungs in the VMAT plans, especially in the PA-VMAT plans. The SA/PA-VMAT plans also reduced treatment time with more efficient dose delivering. But the clinical benefit of the VMAT technique for locally advanced lung cancer needs further investigations.Keywords
This publication has 23 references indexed in Scilit:
- Volumetric-Modulated Arc Therapy for Stereotactic Body Radiotherapy of Lung Tumors: A Comparison With Intensity-Modulated Radiotherapy TechniquesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Choreographing Couch and Collimator in Volumetric Modulated Arc TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Large volume unresectable locally advanced non-small cell lung cancer: acute toxicity and initial outcome results with rapid arcRadiation Oncology, 2010
- Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancerRadiation Oncology, 2010
- Early clinical experience of radiotherapy of prostate cancer with volumetric modulated arc therapyRadiation Oncology, 2010
- A fast radiotherapy paradigm for anal cancer with volumetric modulated arc therapy (VMAT)Radiation Oncology, 2009
- Volumetric Intensity-Modulated Arc Therapy Vs. Conventional IMRT in Head-and-Neck Cancer: A Comparative Planning and Dosimetric StudyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case studyActa Oncologica, 2008
- Comparison of Plan Quality Provided by Intensity-Modulated Arc Therapy and Helical TomotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Factors predicting radiation pneumonitis in lung cancer patients: a retrospective studyRadiotherapy and Oncology, 2003