Dynamic contrast perception assessed by pattern masking.
- 1 March 1998
- journal article
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 15 (3) , 570-578
Abstract
The perceived contrast of a pulsed grating varies markedly with the exposure duration and spatial frequency of the grating. We studied dynamic changes in perceived grating contrast with a pattern-masking paradigm. We measured masking of a brief, localized test pattern (a D6 stimulus, 30 ms in duration) by fixed-contrast cosine grating patterns of varying duration (50-500 ms). The cosine mask pattern had spatial frequency of either 1 or 6 cycles per degree (cpd) at a contrast of 0.3. The D6 test pattern was centered on a light bar of the mask and was either positive peak contrast (same-polarity test and mask) or negative peak contrast (opposite-polarity test and mask). In Experiment 1, the test and mask had simultaneous onset. With a 6-cpd mask, the same-polarity test-threshold elevation versus mask-duration function increases monotonically. For a 1-cpd mask, the same-polarity threshold-mask-duration function is nonmonotonic, with peak masking effect produced by a grating pulse of 80-100 ms. These masking effects are closely congruent with known dynamic contrast effects. With negative tests, masking-duration functions are elevated from same-polarity functions and are essentially similar in shape for 1- and 6-cpd masks. The elevated thresholds suggest inhibitory interaction between ON and OFF pathways, with a similar time course across spatial frequency. In Experiment 2, the D6 test was delayed from mask onset by 33 ms. Positive contrasts only were employed. For 1-cpd stimuli, the delay of test greatly reduced masking at all mask durations and eliminated the nonmonotonic function. This suggests that for low-spatial-frequency patterns, perceived contrast is determined by an early peak component of the neural response. But for 6-cpd stimuli, masking of the delayed test was somewhat greater at all mask durations, consistent with a gradually increasing underlying neural response to the grating. Finally, in Experiment 3, same-polarity masking effects at both spatial frequencies were replicated with negative-contrast test and mask (OFF pathway mediation). This indicates that the ON and OFF pathways have similar response dynamics.Keywords
This publication has 21 references indexed in Scilit:
- Isolation and interaction of ON and OFF pathways in human vision: Contrast discrimination at pattern offsetVision Research, 1997
- Isolation and interaction of ON and OFF pathways in human vision: Pattern-polarity effects on contrast discriminationVision Research, 1995
- A two-process analysis of pattern maskingVision Research, 1994
- The ON and OFF channels of the visual systemTrends in Neurosciences, 1992
- Spatial frequency tuning of orientation selective units estimated by oblique maskingVision Research, 1983
- Temporal impulse and step responses of the human eye obtained psychophysically by means of a drift-correcting perturbation techniqueVision Research, 1981
- Temporal brightness enhancement studied with a large sample of observers: Evidence for individual differences in brightness perceptionPerception & Psychophysics, 1980
- Enhancement of apparent contrast in flashed sinusoidal gratingsVision Research, 1979
- Receptive fields and functional architecture of monkey striate cortexThe Journal of Physiology, 1968
- Visual adaptation in relation to brief conditioning stimuliProceedings of the Royal Society of London. B. Biological Sciences, 1947