Uncertainty of measurement and conformity assessment: a review
- 25 February 2011
- journal article
- review article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (6) , 1729-1741
Abstract
The uncertainty of measurement is the key indicator of the quality of any experimental result. Proper consideration of this uncertainty is imperative when testing a sample against legal/compositional limits. This task can be quite challenging when the entity measured in the investigated sample is so close to the limit that its uncertainty, however estimated, critically affects decision-making. This explains the many literature contributions discussing the problem. Even though some of the most authoritative organisations have issued specific guidelines aimed at assisting the staff involved in such measurements, several aspects of conformity testing are still debated in the literature. In this review, after a short outline of existing information, somewhat more detailed insight is given into the guidelines of ASME, ISO, and Eurachem/CITAC, because they are the most useful tools for operators of testing and calibration laboratories. Some aspects of Council Directive 96/23/EC are also discussed. Insight into the contents of the mentioned documents enables emphasis of analogies and discrepancies. FigureKeywords
This publication has 37 references indexed in Scilit:
- On Conformity Testing and the Use of two Stage ProceduresInternational Statistical Review, 2001
- On the assessment of compliance with legal limits Part 1: signal and concentration domainsAccreditation and Quality Assurance, 2001
- Compliance of analytical results with regulatory or specification limits: a probabilistic approachAccreditation and Quality Assurance, 2001
- Legislative limits below detection capability 1Accreditation and Quality Assurance, 2000
- Assessment of compliance of analytical results with regulatory or specification limitsAccreditation and Quality Assurance, 1999
- Uncertainty of measurement and legislative limitsAccreditation and Quality Assurance, 1998
- Directly Coupled 800 MHz HPLC−NMR Spectroscopy of Urine and Its Application to the Identification of the Major Phase II Metabolites of Tolfenamic AcidAnalytical Chemistry, 1997
- Characterizing and optimizing analytical method qualityTrends in Food Science & Technology, 1996
- Setting and enforcing legislative limitsAnalytical Communications, 1996
- Uncertainty of measurement: implications of its use in analytical scienceThe Analyst, 1995