Intermediate‐term results of the Ex‐PRESS miniature glaucoma implant under a scleral flap in previously operated eyes
- 22 December 2010
- journal article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 39 (5) , 421-428
Abstract
Background: To report the safety and efficacy of Ex‐PRESSTM miniature glaucoma implant under a scleral flap in patients with previous ocular surgeries.Design: Retrospective, non‐comparative case series from a tertiary care hospital.Participants: Patients with previous cataract or failed glaucoma surgeries who had undergone implantation of the Ex‐PRESSTM miniature glaucoma implant (R‐50 and T‐50), under a scleral flap, with a minimum of 1‐year postoperative follow up.Methods: For postoperative outcome, success was defined as complete if intraocular pressure (IOP) was 5–21 mmHg without medication or surgical intervention, and qualified if intraocular pressure was within the same range with glaucoma medication. To compare the outcome between patients who had previous trabeculectomy or cataract surgery the definition of success was intraocular pressure of 5–15 mmHg.Main Outcome Measures: Intraocular pressure, number of antiglaucoma drugs, visual acuity and complications.Results: One hundred eyes (100 patients; mean age: 77.4 years) with a mean follow‐up period of 27 ± 13.2 months (range: 12–66) were considered. Success was complete in 60 (60%) and qualified in 24 (24%) eyes. The mean preoperative IOP of 27.7 ± 9.2 mmHg (range: 14–52 mmHg) with 2.73 ± 1.1 drugs declined to 14.02 ± 5.1 mmHg with 0.72 ± 1.06 drugs at the last follow up (P < 0.0001). Causes of failure were uncontrolled intraocular pressure (11%), bleb needling (4%) and persistent hypotony (1%). The probability of success in the patients with previous cataract surgery and trabeculectomy at 3 years was 60.6% and 50.9%, respectively.Conclusions: The Ex‐PRESSTM implant under scleral flap was a safe and effective glaucoma surgery in the eyes with prior ocular surgery.Keywords
This publication has 26 references indexed in Scilit:
- Evaluation of Ex-PRESS Mini Glaucoma Shunt Implantation in Refractory Postpenetrating Keratoplasty GlaucomaJournal of Glaucoma, 2010
- Subconjunctival insertion of Ex-PRESS R-50 miniature glaucoma implantJournal of Cataract & Refractive Surgery, 2008
- Ex-PRESS R-50 miniature glaucoma implant insertion under the conjunctiva combined with cataract extractionJournal of Cataract & Refractive Surgery, 2007
- Complications Following Ex-Press Glaucoma Shunt ImplantationAmerican Journal of Ophthalmology, 2005
- Optical coherence tomography of the Ex-PRESS miniature glaucoma implantLasers in Medical Science, 2005
- Ex-PRESS implantBritish Journal of Ophthalmology, 2005
- Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsificationBritish Journal of Ophthalmology, 2005
- Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: A clinical pilot studyAmerican Journal of Ophthalmology, 2004
- Contact transscleral neodymium:yttrium–aluminum–garnet laser cyclophotocoagulationLong-term outcomeOphthalmology, 2004
- Delayed Optic Nerve Decompression for Indirect Optic Nerve InjuryThe Laryngoscope, 2003