Optimization of the design of X-Calibur for a long-duration balloon flight and results from a one-day test flight
- 19 March 2018
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Astronomical Telescopes, Instruments, and Systems
- Vol. 4 (01) , 011004-9
Abstract
X-ray polarimetry promises exciting insights into the physics of compact astrophysical objects by providing two observables: the polarization fraction and angle as function of energy. X-Calibur is a balloon-borne hard x-ray scattering polarimeter for the 15- to 60-keV energy range. After the successful test flight in September 2016, the instrument is now being prepared for a long-duration balloon (LDB) flight in December 2018 through January 2019. During the LDB flight, X-Calibur will make detailed measurements of the polarization of Vela X-1 and constrain the polarization of a sample of between 4 and 9 additional sources. We describe the upgraded polarimeter design, including the use of a beryllium scattering element, lower-noise front-end electronics, and an improved fully active CsI(Na) anticoincidence shield, which will significantly increase the instrument sensitivity. We present estimates of the improved polarimeter performance based on simulations and laboratory measurements. We present some of the results from the 2016 flight and show that we solved several problems, which led to a reduced sensitivity during the 2016 flight. We end with a description of the planned Vela X-1 observations, including a Swift/BAT-guided observation strategy.Keywords
Funding Information
- National Aeronautics and Space Administration (NNX10AJ56G)
- National Aeronautics and Space Administration (NNX12AD51G)
- National Aeronautics and Space Administration (NNX14AD19G)
This publication has 28 references indexed in Scilit:
- Phase-resolved X-ray polarimetry of the Crab pulsar with the AstroSat CZT ImagerNature Astronomy, 2017
- Shedding new light on the Crab with polarized X-raysScientific Reports, 2017
- Design of the Telescope Truss and Gondola for the Balloon-Borne X-ray Polarimeter X-CaliburJournal of Astronomical Instrumentation, 2017
- The Imaging X-ray Polarimetry Explorer (IXPE)2016
- The Imaging X-ray Polarimetry Explorer (IXPE)Results in Physics, 2016
- Design and Performance of the X-ray Polarimeter X-CaliburJournal of Astronomical Instrumentation, 2014
- Polarization of the Crab Pulsar and Nebula as Observed by the INTEGRAL /IBIS TelescopeThe Astrophysical Journal, 2008
- Polarized Gamma-Ray Emission from the CrabScience, 2008
- A precision measurement of the X-ray polarization of the Crab Nebula without pulsar contaminationThe Astrophysical Journal, 1978
- Evidence for x Rays From Sources Outside the Solar SystemPhysical Review Letters, 1962