Echocardiographic predictors of single versus dual MitraClip device implantation and long‐term reduction of mitral regurgitation after percutaneous repair
- 14 March 2013
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 82 (4) , 673-679
Abstract
Objectives To describe predictors of the number of MitraClip devices implanted during percutaneous repair of mitral regurgitation (MR), and the long‐term reduction in MR. Background In the EVEREST trials, one or two MitraClip devices were implanted to reduce MR, as needed. Methods Preprocedural transthoracic echocardiograms (TTE) and transesophageal echocardiograms (TEE) of 233 subjects who received 1 or 2 MitraClip devices in the EVEREST II Randomized Trial and High‐Risk Study were analyzed. TEEs were reviewed for etiology of MR and pathoanatomic features of the valve, valve apparatus, and the regurgitant jet. Follow‐up MR was assessed by TTE postprocedure and at 12 months. Results Ninety‐seven subjects (42%) had two MitraClip devices implanted. Subjects with quantitatively more severe MR were more likely to receive two devices [mean regurgitant volume (RV) 45.9 ± 21.9 vs. 36.3 ± 18.5 mL, P P = 0.007) and greater baseline RV (OR 1.21 per 10 mL, P = 0.01) were associated with increased odds of implanting two devices. The frequency of 2+ MR or less at discharge was similar regardless of the number of devices implanted. After propensity matching, patients had quantitatively similar MR at twelve‐month follow‐up, regardless of whether one or two MitraClip devices were implanted (P = 0.6). Conclusions Subjects with thicker anterior mitral leaflets and more severe MR were more likely to receive two MitraClip devices. Immediate and long‐term reduction in MR was similar regardless of the number of devices implanted at the time of the procedure.Keywords
This publication has 22 references indexed in Scilit:
- Acute and 12-Month Results With Catheter-Based Mitral Valve Leaflet RepairJACC, 2012
- Anatomy of the Mitral Valvular Complex and Its Implications for Transcatheter Interventions for Mitral RegurgitationJACC, 2010
- The EVEREST II Trial: Design and rationale for a randomized study of the evalve mitraclip system compared with mitral valve surgery for mitral regurgitationAmerican Heart Journal, 2010
- Percutaneous mitral valve repair with the MitraClip system: acute results from a real world settingEuropean Heart Journal, 2010
- Acute outcomes of MitraClip therapy for mitral regurgitation in high-surgical-risk patients: emphasis on adverse valve morphology and severe left ventricular dysfunctionEuropean Heart Journal, 2010
- Percutaneous Mitral Repair With the MitraClip SystemJACC, 2009
- Active Adaptation of the Tethered Mitral ValveCirculation, 2009
- Quantitative Assessment of Severity of Mitral Regurgitation by Serial Echocardiography in a Multicenter Clinical Trial of Percutaneous Mitral Valve RepairThe American Journal of Cardiology, 2007
- Echocardiographic Guidance and Assessment of Percutaneous Repair for Mitral Regurgitation With the Evalve MitraClip: Lessons Learned From EVEREST IJournal of the American Society of Echocardiography, 2007
- Mitral valve hemodynamic effects of percutaneous edge‐to‐edge repair with the MitraClip™ device for mitral regurgitationCatheterization and Cardiovascular Interventions, 2006