Automatic optic nerve head localization and cup-to-disc ratio detection using state-of-the-art deep-learning architectures
Authors:
Open Access
- 19 March 2020
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-10
Abstract
Computer vision has greatly advanced recently. Since AlexNet was first introduced, many modified deep learning architectures have been developed and they are still evolving. However, there are few studies comparing these architectures in the field of ophthalmology. This study compared the performance of various state-of-the-art deep-learning architectures for detecting the optic nerve head and vertical cup-to-disc ratio in fundus images. Three different architectures were compared: YOLO V3, ResNet, and DenseNet. We compared various aspects of performance, which were not confined to the accuracy of detection but included, as well, the processing time, diagnostic performance, effect of the graphic processing unit (GPU), and image resolution. In general, as the input image resolution increased, the classification accuracy, localization error, and diagnostic performance all improved, but the optimal architecture differed depending on the resolution. The processing time was significantly accelerated with GPU assistance; even at the high resolution of 832 × 832, it was approximately 170 ms, which was at least 26 times slower without GPU. The choice of architecture may depend on the researcher’s purpose when balancing between speed and accuracy. This study provides a guideline to determine deep learning architecture, optimal image resolution, and the appropriate hardware.Keywords
This publication has 25 references indexed in Scilit:
- Automatic Feature Learning for Glaucoma Detection Based on Deep Learning2015
- Comparison of optic disc parameters using spectral domain cirrus high‐definition optical coherence tomography and confocal scanning laser ophthalmoscopy in normal eyesActa Ophthalmologica, 2012
- Repeatability of Optic Nerve Head Parameters Measured by Spectral-Domain OCT in Healthy EyesOphthalmic Surgery, Lasers and Imaging Retina, 2011
- Ability of Cirrus HD-OCT Optic Nerve Head Parameters to Discriminate Normal from Glaucomatous EyesOphthalmology, 2011
- Reproducibility of Peripapillary Retinal Nerve Fiber Layer Thickness and Optic Nerve Head Parameters Measured with Cirrus HD-OCT in Glaucomatous EyesInvestigative Ophthalmology & Visual Science, 2010
- Glaucoma risk index:Automated glaucoma detection from color fundus imagesMedical Image Analysis, 2010
- Agreement in Assessing Cup-to-Disc Ratio Measurement Among Stereoscopic Optic Nerve Head Photographs, HRT II, and Stratus OCTJournal of Glaucoma, 2006
- Vertical cup/disc ratio in relation to optic disc size: its value in the assessment of the glaucoma suspectBritish Journal of Ophthalmology, 1998
- Agreement Between Clinicians and an Image Analyzer in Estimating Cup-to-Disc RatiosArchives of Ophthalmology (1950), 1989
- Size of the optic nerve scleral canal and comparison with intravital determination of optic disc dimensionsGraefe's Archive for Clinical and Experimental Ophthalmology, 1988