Determination of Appropriate Soil Model and Parameters for Grounding System of Substation With High Voltage Via Kronecker-Sequenced Genetic Algorithms
Author:
Open Access
- 11 September 2025
- journal article
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- p. 1-12
Abstract
Accurate estimation of a suitable soil model and its parameters from field resistivity measurements, as well as the apparent soil resistivity based on this model,is vital for the reliable design of grounding systems in substations with high voltage. In this study, the two-layer soil model parameters are estimated based onThe Institute of Electrical and Electronics Engineers (IEEE) Standards using Kronecker-sequenced genetic algorithms (GAs), with lower error values compared tothose in the literature. The estimated parameters are upper and lower layer soil resistivities and upper layer depth. Furthermore, grounding grids are individually designed for both uniform and two-layer soil models using Kronecker-sequenced GAs. The design parameters are the number of rods, meshes, and gridburial depth. In the grounding grid designs, in addition to safety requirements, cost minimization is a key objective. Subsequently, the uniform soil model designparameters have been applied to the two-layer soil model, and the two-layer soil model design parameters to the uniform soil model. This approach enabledthe assessment of whether the grounding grid design parameters obtained for one soil model type (uniform or two-layer soil models) could satisfy safety criteria when applied to the other. Thus, conclusions are drawn on the suitability and reliability of uniform and two-layer soil models for grounding system design. Inthis study, without using very expensive commercial software, Kronecker-sequenced GAs are employed for the estimation of two-layer soil model parametersand the apparent soil resistivity corresponding to the uniform soil model, the grounding grid design, and the evaluation of soil model suitability.Cite this article as: B. Gürsu, “Determination of appropriate soil model and parameters for grounding system of substation with high voltage via Kroneckersequenced genetic algorithms,” Turk J Electr Power Energy Syst., Published online September 11, 2025. doi: 10.5152/tepes.2025.25026.Keywords
This publication has 12 references indexed in Scilit:
- Research on Optimal Design of Substation Grounding Grid Based on Layered Soil Model2025
- Analysis and Optimisation of Grounding Resistance of Substation Based on Gobi Desert Landform2025
- Influence of the use of ground enhancement materials on the reduction of electrical resistivity in grounding systems: a reviewIndonesian Journal of Electrical Engineering and Computer Science, 2024
- Parameters estimation of horizontal multilayer earth based on Kriging model updating methodElectric Power Systems Research, 2024
- The Effect of Soil Type on Touch Voltage and Step Voltage in the Grid Grounding SystemELKHA, 2024
- Optimization of substation grounding grid design for horizontal and vertical multilayer and uniform soil condition using Simulated Annealing methodPLOS ONE, 2021
- Generation of parallel modified Kronecker sequencesMonte Carlo Methods and Applications, 2013
- Resistance to earth of earthing grids buried in multi-layer soilElectrical Engineering, 2005
- Alternative earthing calculations for grids and rodsIEE Proceedings - Generation, Transmission and Distribution, 1998
- Estimation of two layer soil parameters using finite Wenner resistivity expressionsIEEE Transactions on Power Delivery, 1992