Wireless Ultrasound‐Guided Axillary Vein Cannulation for the Implantation of Cardiovascular Implantable Electric Devices
- 12 February 2016
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (4) , 482-487
Abstract
Wireless Ultrasound‐Guided Axillary Vein Cannulation: Introduction: Ultrasound guidance for vascular cannulation seems safer and more effective than an anatomical landmark approach, though it has not gained widespread support partly due to workflow interference of wired probes. A wireless ultrasound transducer (WUST) may overcome this issue. We report the effectiveness, time consumption, and safety of the first‐in‐human experience in axillary vein cannulation guided with a novel WUST for the implantation of cardiovascular implantable electric devices (CIEDs).Methods and Results: After a one‐month training period, we routinely performed WUST‐guided puncture to all first implants, prospectively registering data from the first 50 patients. We analyzed the time needed for preparing the WUST and for achieving each vein cannulation, and the rate of unsuccessful or accidental arterial punctures and complications. WUST‐guided axillary vein access was successful in 49 out of 50 patients, totaling 86 cannulated veins. Median WUST preparation time was 55 [44–62] seconds and median time needed for each venous cannulation was 56 [36–71] seconds. A total of 84.9% of the veins were cannulated at the first attempt. There were 7 unsuccessful puncture attempts and 1 accidental arterial puncture. No pneumothorax, hemothorax, or nervous injury occurred in the 49 successfully cannulated patients. The unsuccessful one (distal subclavian occlusion) developed a minor local subcutaneous emphysema with no confirmed radiologic pneumothorax, not requiring intervention. During a follow‐up of 2.5 ± 1.1 months, a patient developed a pocket infection, with no other significant complications.Conclusion: Ultrasound‐guided axillary vein cannulation using a wireless transducer for the implantation of CIEDs is a feasible, fast, and safe method.Keywords
This publication has 15 references indexed in Scilit:
- Use of Ultrasound Guidance for Central Venous Catheter Placement: Survey From the American Board of Emergency Medicine Longitudinal Study of Emergency PhysiciansAcademic Emergency Medicine, 2014
- Percutaneous Axillary Vein Approach in Pediatric Pacing: Comparison with Subclavian Vein ApproachPacing and Clinical Electrophysiology, 2013
- Ultrasound-guided central venous cannulation is superior to quick-look ultrasound and landmark methods among inexperienced operators: a prospective randomized studyIntensive Care Medicine, 2013
- Axillary Vein Puncture Without Contrast Venography for Pacemaker and Defibrillator Leads ImplantationPacing and Clinical Electrophysiology, 2013
- Ultrasound-Guided Vascular Access: A Comprehensive ReviewJournal of Cardiothoracic and Vascular Anesthesia, 2013
- A Comparison of Lead Placement Through the Subclavian Vein Technique With Fluoroscopy-Guided Axillary Vein Technique for Permanent Pacemaker InsertionCanadian Journal of Cardiology, 2012
- Systematic review: is real-time ultrasonic-guided central line placement by ED physicians more successful than the traditional landmark approach?Emergency Medicine Journal, 2012
- Guidelines for Performing Ultrasound Guided Vascular Cannulation: Recommendations of the American Society of Echocardiography and the Society of Cardiovascular AnesthesiologistsJournal of the American Society of Echocardiography, 2011
- Improved 'cut-down' technique for transvenous pacemaker lead implantationEP Europace, 2010
- Blind Axillary Venous AccessPacing and Clinical Electrophysiology, 1999