Prototype Amperometric Biosensor for Sialic Acid Determination
- 21 December 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (4) , 1668-1674
Abstract
This paper describes the first report on the development, characterization, and applications of a prototype amperometric biosensor for free sialic acid (SA). The sensor was constructed by the coimmobilization of two enzymes, i.e., N-acetylneuraminic acid aldolase and pyruvate oxidase, on a polyester microporous membrane, which was then mounted on top of a platinum disk electrode. The SA biosensor operation was based on the sequential action of the two enzymes to ultimately produce hydrogen peroxide, which was then detected by anodic amperometry at the platinum electrode. The surface of the platinum electrode was coated with an electropolymeric layer to enhance the biosensor selectivity in the presence of interfering oxidizable species. Optimization of the enzyme layer composition resulted in a fast and steady current response in phosphate buffer pH 7.2 at 37 °C. The limit of detection was 10 μM, and the response was linear to 3.5 mM (r = 0.9987). The prepared SA biosensors retained ∼85% of their initial sensitivity after 8 days and showed excellent response reproducibility (CV = 2.3%). Utilization of a third enzyme, sialidase, expanded the scope of the present SA biosensor to determine bound sialic acid as well. The merits of the described biosensor allowed its successful application in determining SA in biological and pharmaceutical samples. The obtained results indicated that the presented SA biosensor should be a useful bioanalytical tool in several biological and clinical applications such as screening of SA as a nonspecific tumor marker as well as monitoring of tumor therapy.Keywords
This publication has 29 references indexed in Scilit:
- Sialic acid: A novel marker of cardiovascular disease?Clinical Biochemistry, 2006
- The role and potential of sialic acid in human nutritionEuropean Journal of Clinical Nutrition, 2003
- The Cellular Biology of Erythropoietin ReceptorsThe Oncologist, 2003
- Review of the use of biosensors as analytical tools in the food and drink industriesFood Chemistry, 2002
- Development of a bienzyme reactor sensor system for the determination of ornithineAnalytica Chimica Acta, 2002
- Development of a new direct reversed-phase ion-pair high-performance liquid chromatographic method for the separation and determination of sialic acidsJournal of Chromatography A, 1999
- Capillary electrophoresis of carboxylated carbohydratesJournal of Chromatography A, 1997
- An improved spectrophotometric method for the determination of free, bound and total N-acetylneuraminic acid in biological fluidsAnalytica Chimica Acta, 1996
- Potentiometric thick-film sensor for the determination of the tumour marker bound sialic acidThe Analyst, 1993
- Enzymatic assay of serum sialic acidClinica Chimica Acta, 1980