Abstract
Zirconium(IV) phosphosulphosalicylate, a cation exchanger was synthesized by mixing zirconium oxychloride to a mixture of 5-sulphosalicylic acid and phosphoric acid. The material showed good efficiency for the preparation of an ion-selective membrane electrode. The membrane was characterized affinity for Pb(II) ions. Due to its Pb(II) selective nature, the ion-exchanger was used as an electroactive by XRD and SEM analysis. The electrode responds to Pb(II) ions in a linear range from 1×10−5 to 1×10−1M with a slope of 43.8mV per decade change in concentration with detection limit of 4.78×10−6M. The life span of electrode was found to be 90days. The proposed electrode showed satisfactory performance over a pH range of 4.0–6.5, with a fast response time of 15s. The sensor has been applied to the determination of Pb(II) ions in water samples of different origins. It has also been used as indicator electrode in potentiometric titration of Pb(II) ion with EDTAKeywords
This publication has 47 references indexed in Scilit:
- Lead-ion potentiometric sensor based on electrically conducting microparticles of sulfonic phenylenediamine copolymerThe Analyst, 2013
- A Comparative Study of Cadmium Ion‐Selective Electrodes with Solid and Liquid Inner ContactElectroanalysis, 2011
- Fabrication of an Er3+ PVC membrane sensor based on oxalic acid bis[2-[(phenylamino)carbonyl]hydrazide]Monatshefte für Chemie - Chemical Monthly, 2010
- Fluoride-selective polymeric membrane electrodes based on Zr(IV)- and Al(III)-salen ionophores of various structuresAnalytica Chimica Acta, 2010
- Development of a Cr(III)-specific potentiometric sensor using Aurin tricarboxylic acid modified silicaAnalytica Chimica Acta, 2005
- Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective ElectrodeSensors, 2004
- Novel coated-graphite membrane sensor based on N,N′-dimethylcyanodiaza-18-crown-6 for the determination of ultra-trace amounts of leadAnalytica Chimica Acta, 2002
- Potentiometric Selectivity Coefficients of Ion-Selective Electrodes. Part I. Inorganic Cations (Technical Report)Pure and Applied Chemistry, 2000
- Lead ion-selective membrane electrodes based on some recently synthesized 9,10-anthraquinone derivativesAnalytica Chimica Acta, 1998
- A cesium-sensitive electrodeAnalytica Chimica Acta, 1971