Assessment of a novel stapler performance for laparoscopic sleeve gastrectomy
- 4 August 2020
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 35 (7) , 4016-4021
Abstract
Background Optimal stapler selection during laparoscopic sleeve gastrectomy requires careful balance between tissue compression, hemostasis, and mechanical integrity. Junctions along a staple line can further increase the risks of technical or mechanical staple line failures. The aim of this study was to compare two commonly utilized laparoscopic linear gastrointestinal staplers (Ethicon, Medtronic) with a novel linear stapler (Titan) designed to perform a sleeve gastrectomy with a single stapler firing. Methods Excised gastric remnants from laparoscopic sleeve gastrectomy were utilized and tissue thickness was measured from fundus to antrum. An optimized experimental staple line was then created. The greater curve remnant was insufflated to determine the staple line burst pressure and location. The doubly stapled (clinical and experimental) gastric specimen underwent staple analysis for junctional location, malformation, and height. Results The Titan stapler withstood a significantly higher burst pressure than both Ethicon and Medtronic linear cutting staplers. While the Medtronic and Ethicon staplers had a similar percentage of staples in junctions, the Titan stapler has no junctions. In considering the formation of all staples outside of junctions, the Medtronic and Titan staplers had no difference in percentage of malformed staples, while the Ethicon stapler had a significantly higher percentage. Additionally, there were no differences in mismatch between staple height and tissue thickness between experimental groups. Conclusions The Titan stapler conveys the mechanical benefits of higher burst pressure with the advantage of single load functionality. This single staple load eliminates staple line junctions without sacrificing the integrity of staple formation.Keywords
This publication has 13 references indexed in Scilit:
- Serosal Laceration During Firing of Powered Linear Stapler Is a Predictor of Staple MalformationSurgical Innovation, 2017
- The bariatric surgery and weight losing: a meta-analysis in the long- and very long-term effects of laparoscopic adjustable gastric banding, laparoscopic Roux-en-Y gastric bypass and laparoscopic sleeve gastrectomy on weight loss in adultsSurgical Endoscopy, 2017
- A Narrative of Intraoperative Staple Line Leaks and Bleeds During Bariatric SurgeryObesity Surgery, 2016
- The proper reload selection during laparoscopic sleeve gastrectomyInternational Journal of Surgery, 2015
- Sleeve gastrectomy. A point of techniqueInternational Journal of Surgery, 2014
- Surgery for weight loss in adultsCochrane Database of Systematic Reviews, 2014
- Human tissue thickness measurements from excised sleeve gastrectomy specimensSurgical Endoscopy, 2013
- Incidence of and risk factors for anastomotic leakage after laparoscopic anterior resection with intracorporeal rectal transection and double-stapling technique anastomosis for rectal cancerThe American Journal of Surgery, 2011
- The importance of precompression time for secure stapling with a linear staplerSurgical Endoscopy, 2010
- Surgical stapler-associated fatalities and adverse events reported to the Food and Drug Administration1,2Journal of the American College of Surgeons, 2004