Numerical modelling of the interaction between dialysis catheter, vascular vessel and blood considering elastic structural deformation
Authors:
- 11 March 2024
- journal article
- research article
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (5) , e3811
Abstract
The dialysis catheter indwelling in human bodies has a high risk of inducing thrombus and stenosis. Biomechanical research showed that such physiological complications are triggered by the wall shear stress of the vascular vessel. This study aimed to assess the impact of CVC implantation on central venous haemodynamics and the potential alterations in the haemodynamic environment related to thrombus development. The SVC structure was built from the images from computed tomography. The blood flow was calculated using the Carreau model, and the fluid domain was determined by CFD. The vascular wall and the CVC were computed using FEA. The elastic interaction between the vessel wall and the flow field was considered using FSI simulation. With consideration of the effect of coupling, it was shown that the catheter vibrated in the vascular systems due to the periodic variation of blood pressure, with an amplitude of up to 10% of the vessel width. Spiral flow was observed along the catheter after CVC indwelling, and recirculation flow appeared near the catheter tip. High OSI and WSS regions occurred at the catheter tip and the vascular junction. The arterial lumen tip had a larger effect on the WSS and OSI values on the vascular wall. Considering FSI simulation, the movement of the catheter inside the blood flow was simulated in the deformable vessel. After CVC indwelling, spiral flow and recirculation flow were observed near the regions with high WSS and OSI values.Keywords
Funding Information
- National Key Research and Development Program of China (2021YFB1715500)
- National Natural Science Foundation of China (6503007607)
This publication has 39 references indexed in Scilit:
- Effects of different non-Newtonian models on unsteady blood flow hemodynamics in patient-specific arterial models with in-vivo validationComputer Methods and Programs in Biomedicine, 2020
- Experimental and Numerical Analysis of the Bulk Flow Parameters Within an Arteriovenous FistulaCardiovascular Engineering and Technology, 2015
- Numerical simulation of the fluid structure interactions in a compliant patient‐specific arteriovenous fistulaInternational Journal for Numerical Methods in Biomedical Engineering, 2013
- Mathematical Problems in Classical and Non-Newtonian Fluid Mechanics2008
- Central Vein Obstruction in Vascular AccessEuropean Journal of Vascular and Endovascular Surgery, 2006
- Central venous catheters: the role of radiologyClinical Radiology, 2006
- To clot or not to clot? That is the question in central venous cathetersClinical Radiology, 2004
- Fluid mechanics of arterial stenosis: Relationship to the development of mural thrombusAnnals of Biomedical Engineering, 1997
- Superior vena cava Doppler flow velocity patterns in pericardial diseaseThe American Journal of Cardiology, 1990
- Early Atherosclerosis and Pulsatile Flow in the Human Carotid Bifurcation1988