Comparison of Glomerular Filtration Rate Measurement Methods between Radionuclide in vivo Scintigraphic Gates’ and Plasma Sampling
Authors:
Open Access
- 30 August 2019
- journal article
- Published by Scientific Foundation Spiroski (publications) in Open Access Macedonian Journal of Medical Sciences
- Vol. 7 (17) , 2734-2738
Abstract
AIM: To correlate between the radionuclide in vitro plasma sampling method (using single and dual blood samples) and Gates’ GFR measurement using Tc-99m diethylene triamine penta-acetic acid (Tc-99m DTPA) renal scintigraphy (in vivo method). METHODS: This study included 40 renal donors (group 1) and 40 patients with obstructive uropathy (group 2). Group 1 included 22 males and 18 females with an age range from 22 to 65 years, while group 2 included 24 males and 16 females with age range 27 to 64 years. Both groups subjected to renal Scintigraphy after administration of 5 mCi 99m-Tc DTPA, GFR was calculated using Gates’ method (in vivo method), then plasma sampling was acquired at 60 mins and 180 mins post-injection of the tracer, samples were counted in well counter and GFR was calculated using in vitro technique either using single plasma sample (SPSM 60 mins) or dual sample (DPSM 60 & 180 min). Additionally, GFR was measured by estimated equations based on serum creatinine. RESULTS: In group 1, the mean GFR using in vivo Gates’ method was 115.7 ± 29 ml/min, while using the SPSM was 100.1 ± 16.1 ml/min, and the DPSM was 100.3 ± 20.1 ml/min. In group 2, mean GFR using in vivo method was 74.1 ± 14.5 ml/min, while using in vitro SPSM it was 77.5 ± 24.9 ml/min and DPSM was 76.8 ± 24.8 ml/min. There was no significant difference between mean GFR values using in vivo and in vitro methods (single or dual samples) in group 1 and 2 (p > 0.05). There is high significant correlation between SPSM and DPSM in groups 1 and 2 (r = 0.90, r = 0.91 respectively), moderate significant correlation was found between in vivo Gates’ method and in vitro SPSM in group 1 and 2 (r = 0.46 and 0.57 respectively) and moderate correlation was evident between in vivo and in vitro DPSM in both groups (r = 0.42 and 0.68 respectively). By using the DPSM as the reference standard significant high correlation was found with SPSM and significant-high moderate correlation with in vivo Gates’ scintigraphic method. Conclusion: In vitro plasma sampling considered as a reliable, accurate |method for GFR calculation yet it considered relatively complex, both single and dual sample in vitro techniques showed a very high correlation, and hence SPSM can replace DPSM. CONCLUSION: Renal scintigraphy and GFR estimation using Gates’ in vivo method is considered inaccurate, yet given its simplicity in performance it can still be used if corrected GFR is standardised for Egyptian population-based on studies with large numbers of patients from multiple centres.Keywords
This publication has 15 references indexed in Scilit:
- Estimating equations for glomerular filtration rate in the era of creatinine standardization: a systematic review.Annals of Internal Medicine, 2012
- Performance of creatinine clearance equations on the original Cockcroft-Gault populationClinical Nephrology, 2006
- Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample methodAnnals of Nuclear Medicine, 2003
- Prevalence of chronic kidney disease and decreased kidney function in the adult US population: Third national health and nutrition examination surveyAmerican Journal of Kidney Diseases, 2003
- Report of the Radionuclides in Nephrourology Committee on Renal ClearanceJournal of Urology, 1998
- Assessment of glomerular filtration rate in diabetic nephropathy using the plasma clearance of 51 Cr-EDTAScandinavian Journal of Clinical and Laboratory Investigation, 1998
- METHODS FOR MEASURING GFR WITH TECHNETIUM-99M-DTPA - AN ANALYSIS OF SEVERAL COMMON METHODS1990
- Measurement of glomerular filtration rate: single injection plasma clearance method without urine collection.1985
- Computation of glomerular filtration rate with Tc-99m DTPA: an in-house computer program.1984
- Glomerular filtration rate: estimation from fractional renal accumulation of 99mTc-DTPA (stannous)American Journal of Roentgenology, 1982