Load Ratio Effect on Fracture Resistance Curve of SA312 TP304 under Reverse Cyclic Loading Condition
Author:
- Sang-Young KimSKSang-Young Kim
- 1 June 2017
- journal article
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 34 (6) , 425-429
Abstract
Seismic load induces a reverse cyclic load that alternately applies a tensile and a compressive load to a structure. For nuclear piping material, safety is assessed in terms of fracture toughness. However, test results using a quasi-static load can’t guarantee safety if there is a seismic load. In this paper, the fracture toughness of SA312 TP304 stainless steel, which is used as the safety injection pipe of a nuclear power plant, was estimated by using reverse cyclic loads with different ratios of tensile load to compressive load. The test results using a load ratio of -1 (compressive load / tensile load) show that fracture toughness decreases to approximately 10% against a load ratio of zero. These test results show that the reverse cyclic load must be considered in planning for the safety of nuclear power plants under seismic loads.Keywords
Funding Information
- Ministry of Education
- National Research Foundation of Korea (NRF-2013R1A1A2065159)
This publication has 3 references indexed in Scilit:
- A study on evaluation method of crack tip reverse plastic zone size for the center cracked steel plate model under tension–compression cyclic loadingEngineering Fracture Mechanics, 2015
- A Study on the Fracture Toughness Characteristics of Equivalent Stress Gradient SpecimenJournal of the Korean Society for Precision Engineering, 2014
- The effects of cyclic and dynamic loading on the fracture resistance of nuclear piping steels. Technical report, October 1992--April 19961996