A survey on the use of low flow anaesthesia and the choice of inhalational anaesthetic agents among anaesthesiologists of India
Open Access
- 1 October 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Indian Journal of Anaesthesia
- Vol. 60 (10) , 751-756
Abstract
Background and Aims: With the availability of modern workstations and heightened awareness on the environmental effects of waste anaesthesia gases, anaesthesiologists worldwide are practicing low flow anaesthesia (LFA). Although LFA is being practiced in India, hard evidence on the current practice of the same from anaesthesiologists practicing in India is lacking and hence, we conducted this survey. Methods: A questionnaire containing 16 questions was distributed among a subgroup of anaesthesiologists who attended the 2014 National Conference of Indian Society of Anaesthesiologists. The filled-in questionnaires were computed and analysed with SPSS version 11. Results: The response rate to the survey was 82%. About 73% of the respondents practiced LFA routinely, with 65% having workstations. Most of the anaesthesiologists used fresh gas flows 2 concentrations at a range of 30–40%. ETCO 2 monitoring was used routinely by most whereas use of agent analysers and bispectral index monitoring were restricted. The availability of scavenging system was also limited to only 33.5%. Majority preferred N 2 O as carrier gas and sevoflurane as volatile agent of their choice. Conclusion: Our survey revealed that practice of LFA in India has numerous lacunae. Provision of better monitoring facilities, workstations as well as awareness regarding the environmental issues of waste anaesthetic gases need to be addressed.Keywords
This publication has 11 references indexed in Scilit:
- Inhalational anaesthesia with low fresh gas flowIndian Journal of Anaesthesia, 2013
- Environmental Implications of Anesthetic GasesAnesthesia Progress, 2012
- Anesthesia : Contributing to pollution?Journal of Anaesthesiology Clinical Pharmacology, 2011
- Global Warming Potential of Inhaled AnestheticsAnesthesia & Analgesia, 2010
- Nitrous Oxide (N 2 O): The Dominant Ozone-Depleting Substance Emitted in the 21st CenturyScience, 2009
- Low-Flow AnaesthesiaPharmacoEconomics, 2000
- Individualized Feedback of Volatile Agent Use Reduces Fresh Gas Flow Rate, but Fails to Favorably Affect Agent ChoiceAnesthesiology, 1999
- Low‐flow anaesthesiaAnaesthesia, 1995
- Low‐flow anaesthesiaAnaesthesia, 1991
- Occupational disease among operating room personnel: a national study. Report of an Ad Hoc Committee on the Effect of Trace Anesthetics on the Health of Operating Room Personnel, American Society of Anesthesiologists.1974