Gerbode defect secondary to tricuspid valve endocarditis: a case report
Authors:
- Roberto Ramos BarbosaRBRoberto Ramos Barbosa
- Layla Pasolini LottLLLayla Pasolini Lott
- Layane Bonfante BatistaLBLayane Bonfante Batista
- Anna Júlia Curcio de Paula AllemandAAAnna Júlia Curcio de Paula Allemand
- Vinicius Eduardo Araújo CostaVCVinicius Eduardo Araújo Costa
- Sergio Luís Santos GuedesSGSergio Luís Santos Guedes
- Bárbara Keller SchreiberBSBárbara Keller Schreiber
- Lucas Crespo de BarrosLBLucas Crespo de Barros
- Rodolfo Costa SylvestreRSRodolfo Costa Sylvestre
- Luiz Fernando Machado BarbosaLBLuiz Fernando Machado Barbosa
Open Access
- 12 February 2026
- journal article
- Published by Open Exploration Publishing in Exploration of Cardiology
- Vol. 4, 101296
Abstract
The Gerbode defect is characterized by a high ventricular septal defect associated with a defect in the septal leaflet of the tricuspid valve, allowing blood to enter the right atrium from the left ventricle. It accounts for approximately 0.08% of intracardiac shunts and may be congenital or acquired. We describe a rare case of Gerbode defect secondary to tricuspid valve endocarditis. A 58-year-old male patient presented with acute infective endocarditis due to Staphylococcus aureus, related to central venous access. Echocardiography showed a tricuspid valve with thickened leaflets and a small mobile image on the atrial side of the septal leaflet, as well as moderate to severe regurgitation. After completion of the antibiotic regimen with resolution of the infectious condition, the patient was discharged asymptomatic, and a new echocardiogram showed no vegetation on the tricuspid valve. During outpatient follow-up, he presented dyspnea on mild exertion, and consecutive echocardiograms showed moderate tricuspid insufficiency and significant pulmonary hypertension with a pulmonary artery systolic pressure of 83 mmHg (reference: 30 mmHg). He underwent right and left cardiac catheterization, which showed a Gerbode defect, and a transesophageal echocardiogram showed a shunt in the subaortic region measuring 6 to 8 mm, with a maximum gradient of 56 mmHg. He underwent elective surgery to correct the Gerbode defect and tricuspid valve repair, with a good clinical result. The Gerbode defect is rare, and the diagnosis can be challenging because it simulates other conditions. Treatment consists of closing the defect when it generates refractory symptoms or complications. The reported case was surgically corrected, with a good result and favorable evolution.Keywords
This publication has 8 references indexed in Scilit:
- The Gerbode defect: a case seriesEuropean Heart Journal - Case Reports, 2021
- Gerbode defect: A comprehensive review of its history, anatomy, embryology, pathophysiology, diagnosis, and treatmentJournal of the Saudi Heart Association, 2017
- Acquired Gerbode defect following endocarditis of the tricuspid valve: a case report and literature reviewJournal of Cardiothoracic Surgery, 2015
- Gerbode defect: Another nail for the 3D transesophagel echo hammer?The International Journal of Cardiovascular Imaging, 2015
- Gerbode Defect—A Rare Defect of Atrioventricular Septum and Tricuspid ValveJournal of Clinical and Diagnostic Research, 2015
- Expert review Left ventricular to right atrial shunt (Gerbode defect): congenital versus acquiredAdvances in Interventional Cardiology, 2014
- Left ventricular—Right atrial communicationThe American Journal of Cardiology, 1967
- Syndrome of Left Ventricular-Right Atrial Shunt Successful Surgical Repair of Defect in Five Cases, with Observation of Bradycardia on ClosureAnnals of Surgery, 1958