Biomechanical Assessment of Anterior Lumbar Interbody Fusion With an Anterior Lumbosacral Fixation Screw-Plate: Comparison to Stand-Alone Anterior Lumbar Interbody Fusion and Anterior Lumbar Interbody Fusion With Pedicle Screws in an Unstable Human Cadaver Model
Authors:
- Neil R. CrawfordNCNeil R. Crawford
- Robert H. ChamberlainRCRobert H. Chamberlain
- Mary S. FifieldMFMary S. Fifield
- Jean-Charles LeHuecJLJean-Charles LeHuec
- Curtis A. DickmanCDCurtis A. Dickman
- 1 April 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 31 (7) , 762-768
Abstract
Human lumbosacral cadaveric specimens were tested in an in vitro biomechanical flexibility experiment using physiologic loads in 5 sequential conditions. To determine the biomechanical differences between anterior lumbar interbody fusion (ALIF) using cylindrical threaded cages alone or supplemented with an anterior screw-plate or posterior pedicle screws-rods. Clinically and biomechanically, stand-alone ALIF performs modestly in immobilizing the unstable spine. Pedicle screws improve fixation stiffness significantly, but supplementary anterior instrumentation has not been studied. There were 7 specimens tested: (1) intact, (2) after discectomy and facetectomy to induce moderate rotational and translational hypermobility, (3) with 2 parallel ALIF cages, (4) with cages plus a triangular anterior screw-plate, and (5) with cages plus pedicle screws-rods. Pure moments without preload induced flexion, extension, lateral bending, and axial rotation; linear shear forces induced anteroposterior translation. Angular and linear motions were measured stereophotogrammetrically, and range of motion (ROM) and stiffness were quantified. Compared to the destabilized spine, interbody cages alone reduced ROM by 77% during flexion, 53% during extension, 60% during lateral bending, 69% during axial rotation, and 71% during anteroposterior shear (P < 0.001, analysis of variance/Fisher least significant difference). Addition of an anterior plate or pedicle screws-rods, respectively, further reduced ROM by 8% or 13% during flexion (P = 0.21), 21% or 28% during extension (P = 0.15), 5% or 25% during lateral bending (P = 0.04), 11% or 18% during axial rotation (P = 0.13), and 18% or 18% during anteroposterior shear (P = 0.17). Compared to stand-alone ALIF, both the anterior screw-plate and pedicle screw-rod fixation reduced vertebral ROM to less than 1.2 degrees of rotation and less than 0.1 mm of translation. The anterior screw-plate and pedicle screws-rods both substantially reduced ROM and increased stiffness compared to stand-alone interbody cages. There was no significant difference in the amount by which the supplementary fixation devices limited flexion, extension, axial rotation, or anteroposterior shear; pedicle screws-rods better restricted lateral bending.Keywords
This publication has 23 references indexed in Scilit:
- Minimally invasive anterior lumbar interbody fusion followed by percutaneous pedicle screw fixation for isthmic spondylolisthesisThe Spine Journal, 2004
- Effect of Supplemental Translaminar Facet Screw Fixation on the Stability of Stand-Alone Anterior Lumbar Interbody Fusion Cages Under Physiologic Compressive PreloadsSpine, 2004
- A Prospective, Randomized Controlled Clinical Trial of Anterior Lumbar Interbody Fusion Using a Titanium Cylindrical Threaded Fusion DeviceSpine, 2004
- Intervertebral cages for degenerative spinal diseasesThe Spine Journal, 2003
- Biomechanics of Grade I degenerative lumbar spondylolisthesis. Part 2: Treatment with threaded interbody cages/dowels and pedicle screwsJournal of Neurosurgery: Spine, 2001
- Biomechanics of stand-alone cages and cages in combination with posterior fixation: a literature reviewEuropean Spine Journal, 2000
- The role of supplemental translaminar screws in anterior lumbar interbody fixation: a biomechanical studyEuropean Spine Journal, 1998
- Interbody cage stabilisation in the lumbar spine: biomechanical evaluation of cage design, posterior instrumentation and bone density.The Journal of Bone and Joint Surgery. British volume, 1998
- An Apparatus for Applying Pure Nonconstraining Moments to Spine Segments In VitroSpine, 1995
- Biomechanical Evaluation of Spinal Fixation DevicesSpine, 1988