Exposure to varying levels of contaminants and symptoms among workers in two office buildings.
Authors:
- R M TamblynRTR M Tamblyn
- F NunesFNF Nunes
- J HanleyJHJ Hanley
- R T TamblynRTR T Tamblyn
- 1 November 1996
- journal article
- clinical trial
- Published by American Public Health Association in American Journal of Public Health
- Vol. 86 (11) , 1629-1633
Abstract
OBJECTIVES: We hypothesized that exposure to contaminants would be associated with symptoms reported by office workers. METHODS: In two mechanically ventilated office buildings in. Montreal, the outdoor air supply was manipulated for 6 weeks, while symptoms were reported and environmental parameters were measured at multiple sites. RESULTS: Contaminant concentrations varied considerably, in part related to experimental changes in outdoor air supply. Eye symptoms were reported with higher dust and with higher concentrations of nitrogen dioxide. Mucosal symptoms were increased with higher TVOCs, higher nitrogen dioxide, and higher total contaminant load. Systemic symptoms were associated with higher dust levels. CONCLUSIONS: Symptoms reported by the workers were associated with increased concentrations of several contaminants and a summary measure of all contaminants.Keywords
This publication has 13 references indexed in Scilit:
- The Effect of Varying Levels of Outdoor-Air Supply on the Symptoms of Sick Building SyndromeNew England Journal of Medicine, 1993
- The feasibility of using a double blind experimental cross-over design to study interventions for sick building syndromeJournal of Clinical Epidemiology, 1992
- Effect of low concentrations of ozone on inhaled allergen responses in asthmatic subjectsThe Lancet, 1991
- Volatile organic compounds, respirable dust, and personal factors related to prevalence and incidence of sick building syndrome in primary schools.Occupational and Environmental Medicine, 1990
- SICK BUILDING SYNDROME: A STUDY OF 4373 OFFICE WORKERSAnnals of Occupational Hygiene, 1987
- The “sick” building syndrome in the office environment: The Danish town hall studyEnvironment International, 1987
- Formaldehyde odor and its interaction with the air of a sick buildingEnvironment International, 1986
- Comparison of health problems related to work and environmental measurements in two office buildings with different ventilation systems.BMJ, 1985
- The sick building syndrome: prevalence studies.BMJ, 1984
- Is the Diagnosis of "Mass Hysteria" an Excuse for Incomplete Investigation of Low-Level Environmental Contamination?Journal of Occupational and Environmental Medicine, 1981