Characterization of the foreign body response to common surgical biomaterials in a murine model
- 28 April 2017
- journal article
- research article
- Published by Springer Nature in European Journal of Plastic Surgery
- Vol. 40 (5) , 383-392
Abstract
Background Implanted biomaterials are subject to a significant reaction from the host, known as the foreign body response (FBR). We quantified the FBR to five materials following subcutaneous implantation in mice. Methods Polyvinyl alcohol (PVA) and silicone sheets are considered highly biocompatible biomaterials and were cut into 8-mm-diameter disks. Expanded PTFE (ePTFE) and polypropylene are also widely used biocompatible biomaterials and were cut into 2 cm-long cylinders. Cotton was selected as a negative control material that would invoke an intense FBR, was cut into disks, and implanted. The implants were inserted subcutaneously into female C57BL/6 mice. On post-implantation days 14, 30, 60, 90, and 180, implants were retrieved. Cellularity was assessed with DAPI stain, collagen with Masson’s trichrome stain, mast cells with toluidine blue, macrophages with F4/80 immunohistochemical stain, and capsular thickness and foreign body giant cells with hematoxylin and eosin. Results DAPI revealed a significantly increased cellularity in both PVA and silicone, and ePTFE had the lowest cell density. Silicone showed the lowest cellularity at day 14 and day 90, whereas ePTFE showed the lowest cellularity at days 30, 60, and 180. Masson’s trichrome staining demonstrated no apparent difference in collagen. Toluidine blue showed no differences in mast cells. There were, however, fewer macrophages associated with ePTFE. On day 14, PVA had highest number of macrophages, whereas polypropylene had the highest number at all time points after d14. Giant cells increased earlier and gradually decreased later. On day 90, PVA exhibited a significantly increased number of giant cells compared to polypropylene and silicone. Silicone consistently formed the thinnest capsule throughout all time points. On day 14, cotton had formed the thickest capsule. On day 30, polypropylene gas formed the thickest capsule, and on days 60, 90, and 180, PVA had formed the thickest capsule. Conclusions These data reveal differences in capsule thickness and cellular response in an implant-related manor, indicating that fibrotic reactions to biomaterials are implant-specific and should be carefully considered when performing studies on fibrosis when biomaterials are being used. Level of Evidence: Not ratableKeywords
Funding Information
- Foundation for the National Institutes of Health (K08 GM 085562-05)
This publication has 25 references indexed in Scilit:
- Foreign body response to subcutaneous biomaterial implants in a mast cell-deficient Kitw-Sh murine modelActa Biomaterialia, 2014
- Dual growth factor releasing multi-functional nanofibers for wound healingActa Biomaterialia, 2013
- The effect of nitric oxide surface flux on the foreign body response to subcutaneous implantsBiomaterials, 2012
- sFRP2 Suppression of Bone Morphogenic Protein (BMP) and Wnt Signaling Mediates Mesenchymal Stem Cell (MSC) Self-renewal Promoting Engraftment and Myocardial RepairJournal of Biological Chemistry, 2010
- The Sponge Implant Model of Angiogenesis2008
- Foreign body reaction to biomaterialsSeminars in Immunology, 2008
- Vitronectin is a critical protein adhesion substrate for IL‐4‐induced foreign body giant cell formationJournal of Biomedical Materials Research Part A, 2007
- Animal models for wound repairArchives of Dermatological Research, 1998
- Wound Collagen Accumulation in Obese Hyperglycemic MiceDiabetes, 1986
- Comparison of fetal, newborn, and adult wound healing by histologic, enzyme-histochemical, and hydroxyproline determinationsJournal of Pediatric Surgery, 1985