The quality of platelet concentrates related to corrected count increment: linking in vitro to in vivo
- 18 September 2018
- journal article
- retraction
- Published by Wiley in Transfusion
- Vol. 59 (2) , 697-706
Abstract
BACKGROUND: Storage of platelet concentrates (PCs) results in reduced recovery and survival of transfused platelets (PLTs). Upon storage PLTs develop storage lesion that can be monitored by several laboratory tests. However, correlation of these descriptive tests with corrected count increments (CCIs), a marker frequently used to establish the effectiveness of PLT transfusions, is limited or unknown. This study investigated to what extent a functional test or a combined in vitro rating score improves the correlation of laboratory tests with 1-hour CCI. STUDY DESIGN AND METHODS: PCs were analyzed using six different laboratory tests (n = 123) before transfusion in a prophylactic setting to 74 hematooncologic patients. Linear regression and Spearman correlation were used to determine associations between descriptive (either separately or combined in an in vitro rating score) or functional test results and 1-hour CCIs obtained after transfusion. RESULTS: CD62P expression (r = -0.45), annexin V binding (r = -0.36), the updated in vitro rating score (r = 0.50), and PLT responsiveness after thrombin receptor activator for peptide-6 (TRAP) (r = 0.43-0.57) or adenosine diphosphate stimulation (r = 0.11-0.51) significantly correlated to 1-hour CCIs obtained after transfusion, whereas lactate concentration, ThromboLUX score, and thromboelastography measurements did not. The strongest correlations were observed for in vitro rating score and PLT responsiveness after TRAP stimulation and these tests could explain 24 and 33% of the observed variation in 1-hour CCI, respectively. CONCLUSION: Combining descriptive markers in one in vitro rating score improved correlation to 1-hour CCI compared to the tests separately. Of all tests investigated, mean PLT responsiveness after TRAP stimulation showed the strongest clinical correlation and was best able to predict the 1-hour CCI.Keywords
Funding Information
- Sanquin (11-003)
This publication has 29 references indexed in Scilit:
- Platelet Activation Test in Unprocessed Blood (Pac-t-UB) to Monitor Platelet Concentrates and Whole Blood of Thrombocytopenic PatientsTransfusion Medicine and Hemotherapy, 2013
- Transfused stored platelets have the same haemostatic function as circulating native plateletsVox Sanguinis, 2010
- In vitrocomparison of platelet storage in plasma and in four platelet additive solutions, and the effect of pathogen reduction: a proposal for anin vitrorating systemVox Sanguinis, 2010
- Platelet quality measured with dynamic light scattering correlates with transfusion outcome in hematologic malignanciesTransfusion, 2009
- In vitro assays used in the evaluation of the quality of stored platelets: Correlation with in vivo assaysTransfusion and Apheresis Science, 2008
- Patient and product factors affecting platelet transfusion resultsTransfusion, 2008
- Impairment of the hemostatic potential of platelets during storage as evaluated by flow cytometry, thrombin generation, and thrombelastography under conditions promoting formation of coated plateletsTransfusion, 2007
- Further evaluation of a new standard of efficacy for stored plateletsTransfusion, 2005
- Factors affecting posttransfusion platelet increments, platelet refractoriness, and platelet transfusion intervals in thrombocytopenic patientsBlood, 2005
- Factors influencing 20‐hour increments after platelet transfusionTransfusion, 1991