Abstract
The single-ended and double-ended forward converters are compared using the failure-rate and the mean time between failures (MTBF), which are representative indices of reliability. In addition to the part count analysis (PCA), which considers only the type of parts, the number of parts, and the connection status of parts, the reliability is analyzed by applying the fault-tree concept to reflect the operational risks of the converter. In the proposed fault-tree based analysis, the lowest failure event of the fault-tree, which indicates the cause and effect of the converter fault, uses the failure library of MIL-HDBK-217F. The cause and meaning of the failure-rate difference obtained by the PCA and the proposed FTA are explained, and finally we draw a conclusion that the single-ended forward converter is more advantageous in the viewpoint of reliability than the double-ended forward converter.

This publication has 6 references indexed in Scilit: