Abstract
The increase in energy efficiency of the traction electric drive of a shunting diesel locomotive is considered. It is shown that when the number of operating traction electric motors changes, the efficiency of the traction electric drive changes, which can be used to improve the traction and energy performance of the diesel locomotive. The use of the average efficiency as a criterion for selecting the rational number of operating electric motors is proposed and justified. The average efficiency is determined taking into account the duration of operation of the traction electric drive in a specific operating mode. It is shown that for a shunting diesel locomotive, it is advisable to determine the average efficiency for operating modes that correspond to movement during shunting operations. The energy efficiency of the traction electric drive for shunting operations and haulage work with four and six operating traction electric motors has been investigated. The results of the calculations show that when using four traction motors, the average efficiency is higher. It is advisable to define the operation with four traction motors as the priority operating mode, as the main operating mode of the locomotive. The research results can be used in the modernisation of CHEM3 shunting locomotives with collector traction electric drives. The proposed methodology can be adapted for other locomotives and can also be used in the creation of new rolling stock.