Automated voxel-based prostate volumetry improves PSA density–based detection of clinically significant prostate cancer in the PSA gray zone: comparison with manual segmentation and the ellipsoid formula
Authors:
Open Access
- 7 October 2026
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 8, 1897681
Abstract
Purpose: To investigate whether voxel-based prostate volume can improve the diagnostic performance of prostate-specific antigen density (PSAD) for detecting clinically significant prostate cancer (csPCa) in patients within the prostate-specific antigen (PSA) gray zone (4–10 ng/mL), and to compare it with conventional formula-based estimation. Methods: In this retrospective study, 489 patients with PSA levels of 4–10 ng/mL who underwent prostate MRI were included. Prostate volumes were calculated using three methods ellipsoid formula ( PV formula ), manual voxel-based segmentation ( PV mask ), and automated voxel-based segmentation ( PV auto_seg ) based on nnU-Net. Agreement between volumetric measurements was assessed using Bland–Altman analysis, and PSAD was calculated according to three prostate volume estimations. Diagnostic performance for the detection of csPCa was evaluated using receiver operating characteristic (ROC) analysis. Results: PV formula systematically overestimated prostate volume compared with PV mask , with mean volumes of 58.8 ± 28.1 mL and 54.5 ± 26.6 mL (bias 4.4 mL); whereas PV auto_seg (55.8 ± 20.8 mL) showed close agreement with PV mask and reduced bias of 1.4 mL. In ROC analysis, voxel-based PSAD mask (AUC 0.762, 95% CI 0.717–0.808) outperformed the formula-based PSAD formula (AUC 0.719, 95% CI 0.671–0.767; P = 0.01). PSAD auto_seg calculated from PV auto_seg yielded an AUC similar (0.754, 95% CI 0.707–0.800) to that of with PSAD mask , and also outperformed PSAD formula ( P = 0.02). Conclusion: Voxel-based prostate volumetry provides more accurate and consistent volume estimation than the conventional ellipsoid formula, leading to improved PSAD performance for detecting csPCa in the PSA gray zone. Moreover, automated segmentation enables reliable and scalable PSAD calculation with diagnostic performance comparable to manual delineation, supporting its potential for clinical implementation in risk stratification of PCa.Keywords
This publication has 34 references indexed in Scilit:
- Diagnostic Performance of Prostate-specific Antigen Density for Detecting Clinically Significant Prostate Cancer in the Era of Magnetic Resonance Imaging: A Systematic Review and Meta-analysisEuropean Urology Oncology, 2023
- Investigation and benchmarking of U-Nets on prostate segmentation tasksComputerized Medical Imaging and Graphics, 2023
- Automated prostate multi-regional segmentation in magnetic resonance using fully convolutional neural networksEuropean Radiology, 2023
- Deep learning algorithm performs similarly to radiologists in the assessment of prostate volume on MRIEuropean Radiology, 2022
- Prostate158 - An expert-annotated 3T MRI dataset and algorithm for prostate cancer detectionComputers in Biology and Medicine, 2022
- Prostate volume prediction on MRI: tools, accuracy and variabilityEuropean Radiology, 2022
- Prostate Volume Estimation on MRI: Accuracy and Effects of Ellipsoid and Bullet-Shaped Measurements on PSA DensityAcademic Radiology, 2021
- Determination of Prostate VolumeAcademic Radiology, 2018
- Systematic Review of Complications of Prostate BiopsyEuropean Urology, 2013
- ESUR prostate MR guidelines 2012European Radiology, 2012