Mobile and Fixed-Bearing (All-Polyethylene Tibial Component) Total Knee Arthroplasty Designs
- 1 September 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 91 (9) , 2104-2112
Abstract
Background: Proponents of mobile-bearing total knee arthroplasty believe that it has potential advantages over a fixed-bearing design in terms of diminished wear and improved motion and/or function, but these advantages have not been demonstrated in a randomized clinical comparison to our knowledge. We conducted a patient-blinded, prospective, randomized clinical trial to compare mobile-bearing and fixed-bearing cruciate-substituting total knee arthroplasties of the same design. Methods: Patients between the ages of sixty and eighty-five years were prospectively randomized to receive a cruciate-substituting rotating-platform design or a fixed-bearing design with an all-polyethylene tibial component. There were no significant differences in the demographic characteristics (mean age, 72.2 years; mean American Society of Anesthesiologists score, 2.7; mean body mass index, 31.8 kg/m2) or preoperative clinical or radiographic measures between the groups. Routine clinical and radiographic follow-up measures included the Knee Society score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and Short Form-36 (SF-36) outcome measures. Results: The results of 312 arthroplasties (136 with an all-polyethylene tibial component and 176 rotating-platform designs) in 273 patients were analyzed at a minimum of two years (mean, forty-two months) postoperatively. Although there was significant improvement in both groups, there was no significant difference between the groups with regard to the mean postoperative range of motion (110.9° and 109.1°, respectively; p = 0.21), the mean KSS clinical score (90.4 and 88.2 points; p = 0.168), or the mean KSS pain score (44.9 and 43.1 points; p = 0.108) at this follow-up point. There were ten revisions: seven because of infection, one because of patellar fracture, one because of instability, and one because of aseptic loosening. Conclusions: The two designs functioned equivalently at the time of early follow-up in this low-to-moderate-demand patient group. The rotating-platform design had no significant clinical advantage over the design with the all-polyethylene tibial component. Level of Evidence: Therapeutic Level I. See Instructions to Authors for a complete description of levels of evidence.Keywords
This publication has 22 references indexed in Scilit:
- Extending the CONSORT Statement to Randomized Trials of Nonpharmacologic Treatment: Explanation and ElaborationAnnals of Internal Medicine, 2008
- Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplastyBMC Musculoskeletal Disorders, 2007
- The influence of design, materials and kinematics on the in vitro wear of total knee replacementsJournal of Biomechanics, 2005
- Rotating Platform Knees Did Not Improve Patellar TrackingClinical Orthopaedics and Related Research, 2004
- Why Are Total Knee Replacements Revised?Clinical Orthopaedics and Related Research, 2004
- Mobile-Bearing Knee Replacement: Clinical ResultsClinical Orthopaedics and Related Research, 2001
- Matched-pair analysis of all-polyethylene versus metal-backed tibial componentsThe Journal of Arthroplasty, 2001
- Comparison of metal-backed and all-polyethylene tibial components in cruciate condylar total knee arthroplastyThe Journal of Arthroplasty, 1993
- The MOS 36-ltem Short-Form Health Survey (SF-36)Medical Care, 1992
- The New Jersey low-contact-stress knee replacement system: Biomechanical rationale and review of the first 123 cemented casesArchives of orthopaedic and trauma surgery, 1986