Language-dependent diagnostic safety of medical AI systems: a cross-lingual benchmarking and prospective clinical study
Preprint
Abstract
Summary: Background: Patients worldwide receive healthcare in many languages, yet medical AI systems are validated almost exclusively in high-resource languages such as English and Chinese, exposing patients in other linguistic settings to unquantified diagnostic risk. Existing multilingual evaluations rely on translated research-style benchmarks that fail to capture authentic clinical work. We aimed to characterise the patient safety consequences of multilingual medical AI deployment in real-world clinical settings and to develop an auditable detection method for unsafe outputs. Methods: We evaluated different language models(LLMs) and visual language models(VLMs) across four real-world clinical tasks (conversational QA, radiology report generation, glaucoma diagnosis, ICU re-intubation prediction) in five languages (English, Chinese, Malay, Thai, Persian). We developed a token-level uncertainty toolkit to localise reasoning instability, com pared three inference paradigms (native-language, English chain-of-thought, back-translation pivot), and conducted a prospective study (50 dialogues, 150 physician-reviewed records). Findings: LLMs/VLMs performance degraded consistently from high-to low-resource languages across al l tasks. Key gaps included: HealthBench score declining from 0·3743 to 0·3180; radiology macro-F1 from 0·2938 to 0·2149–0·2424, consistent with selective pathology suppression; glaucoma accuracy from 50·7% to 32·7%; ICU parameter recall from 100·0% to 48·5%. Multimodal inputs amplified degradation. Qwen3 VL 235B showed attenuated decline with no re source-ordered pattern in glaucoma classification. Token-level analysis localised instability to mid-chain stages (40–70% of the normalised trajectory); perplexity-based confidence failed to flag errors (AUROC 0·41–0·66). Back-translation pivot consistently restored performance. In the prospective study, 98·7% of records required physician edits (overall modification score 53·6%); Thai-pivot correction burden (59·0%) exceeded English-pivot (5 0·7%, p=0·003) and Chinese-direct (51·0%, p=0·004). Interpretation: Multilingual deployment produced clinically consequential failures, including missed pathology, distorted physiological extraction, and amplified multimodal misclassification, that were invisible to monolingual validation and not reliably flagged by model confidence. Pre training data composition may contribute to multilingual safety risk. Language-specific safety auditing should precede deployment in non-dominant-language healthcare settings; the open-source detection toolkit enables this without model retraining.Keywords
This publication has 19 references indexed in Scilit:
- Large language models in medicineNature Medicine, 2023
- Large language models encode clinical knowledgeNature, 2023
- The imperative for regulatory oversight of large language models (or generative AI) in healthcarenpj Digital Medicine, 2023
- Foundation models for generalist medical artificial intelligenceNature, 2023
- Multimodal biomedical AINature Medicine, 2022
- AI in health and medicineNature Medicine, 2022
- Underdiagnosis bias of artificial intelligence algorithms applied to chest radiographs in under-served patient populationsNature Medicine, 2021
- MIMIC-CXR, a de-identified publicly available database of chest radiographs with free-text reportsScientific Data, 2019
- Dissecting racial bias in an algorithm used to manage the health of populationsScience, 2019
- MIMIC-III, a freely accessible critical care databaseScientific Data, 2016