Follow-Up Assessment of Intracranial Aneurysms Treated with Endovascular Coiling: Comparison of Compressed Sensing and Parallel Imaging Time-of-Flight Magnetic Resonance Angiography
Authors:
- Gianfranco VornettiGVGianfranco Vornetti
- Fiorina BartiromoFBFiorina Bartiromo
- Francesco ToniFTFrancesco Toni
- Massimo Dall’olioMDMassimo Dall’olio
- Mario CirilloMCMario Cirillo
- Peter SpeierPSPeter Speier
- Ciro PrinciottaCPCiro Princiotta
- Michaela SchmidtMSMichaela Schmidt
- Caterina TononCTCaterina Tonon
- Domenico ZacàDZDomenico Zacà
- Raffaele LodiRLRaffaele Lodi
- Luigi CirilloLCLuigi Cirillo
Open Access
- 18 June 2022
- journal article
- research article
- Published by MDPI AG in Tomography
- Vol. 8 (3) , 1608-1617
Abstract
The aim of our study was to compare compressed sensing (CS) time-of-flight (TOF) magnetic resonance angiography (MRA) with parallel imaging (PI) TOF MRA in the evaluation of patients with intracranial aneurysms treated with coil embolization or stent-assisted coiling. We enrolled 22 patients who underwent follow-up imaging after intracranial aneurysm coil embolization. All patients underwent both PI TOF and CS TOF MRA during the same examination. Image evaluation aimed to compare the performance of CS to PI TOF MRA in determining the degree of aneurysm occlusion, as well as the depiction of parent vessel and vessels adjacent to the aneurysm dome. The reference standard for the evaluation of aneurysm occlusion was PI TOF MRA. The inter-modality agreement between CS and PI TOF MRA in the evaluation of aneurysm occlusion was almost perfect (κ = 0.98, p < 0.001) and the overall inter-rater agreement was substantial (κ = 0.70, p < 0.001). The visualization of aneurysm parent vessel in CS TOF images compared with PI TOF images was evaluated to be better in 11.4%, equal in 86.4%, and worse in 2.3%. CS TOF MRA, with almost 70% scan time reduction with respect to PI TOF MRA, yields comparable results for assessing the occlusion status of coiled intracranial aneurysms. Short scan times increase patient comfort, reduce the risk of motion artifacts, and increase patient throughput, with a resulting reduction in costs. CS TOF MRA may therefore be a potential replacement for PI TOF MRA as a first-line follow-up examination in patients with intracranial aneurysms treated with coil embolization.Keywords
This publication has 34 references indexed in Scilit:
- The effectiveness of 3T time-of-flight magnetic resonance angiography for follow-up evaluations after the stent-assisted coil embolization of cerebral aneurysmsActa Radiologica, 2014
- Epidemiology and genetics of intracranial aneurysmsEuropean Journal of Radiology, 2013
- MRA Versus DSA for Follow-Up of Coiled Intracranial Aneurysms: A Meta-AnalysisAmerican Journal of Neuroradiology, 2013
- Follow-Up of Coiled Intracranial Aneurysms: Comparison of 3D Time-of-Flight MR Angiography at 3T and 1.5T in a Large Prospective SeriesAmerican Journal of Neuroradiology, 2012
- A Prospective Trial of 3T and 1.5T Time-of-Flight and Contrast-Enhanced MR Angiography in the Follow-Up of Coiled Intracranial AneurysmsAmerican Journal of Neuroradiology, 2009
- The Safety of Dedicated-Team Catheter-Based Diagnostic Cerebral Angiography in the Era of Advanced Noninvasive ImagingAmerican Journal of Neuroradiology, 2009
- Evaluation of the Occlusion Status of Coiled Intracranial Aneurysms with MR Angiography at 3T: Is Contrast Enhancement Necessary?American Journal of Neuroradiology, 2009
- Follow-Up of Coiled Cerebral Aneurysms at 3T: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR AngiographyAmerican Journal of Neuroradiology, 2008
- International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trialThe Lancet, 2002
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002