Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves
Open Access
- 30 March 2017
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 55 (11) , 1989-2000
Abstract
Photoplethysmography (PPG) is a widely available non-invasive optical technique to visualize pressure pulse waves (PWs). Pulse transit time (PTT) is a physiological parameter that is often derived from calculations on ECG and PPG signals and is based on tightly defined characteristics of the PW shape. PPG signals are sensitive to artefacts. Coughing or movement of the subject can affect PW shapes that much that the PWs become unsuitable for further analysis. The aim of this study was to develop an algorithm that automatically and objectively eliminates unsuitable PWs. In order to develop a proper algorithm for eliminating unsuitable PWs, a literature study was conducted. Next, a ‘7Step PW-Filter’ algorithm was developed that applies seven criteria to determine whether a PW matches the characteristics required to allow PTT calculation. To validate whether the ‘7Step PW-Filter’ eliminates only and all unsuitable PWs, its elimination results were compared to the outcome of manual elimination of unsuitable PWs. The ‘7Step PW-Filter’ had a sensitivity of 96.3% and a specificity of 99.3%. The overall accuracy of the ‘7Step PW-Filter’ for detection of unsuitable PWs was 99.3%. Compared to manual elimination, using the ‘7Step PW-Filter’ reduces PW elimination times from hours to minutes and helps to increase the validity, reliability and reproducibility of PTT data.Keywords
This publication has 57 references indexed in Scilit:
- Pulse transit time as a surrogate measure of changes in systolic arterial pressure in children during sleepJournal of Sleep Research, 2014
- Bivariate point process modeling and joint non-stationary analysis of pulse transit time and heart period2012
- Pulse transit time as a quick predictor of a successful axillary brachial plexus blockActa Anaesthesiologica Scandinavica, 2012
- Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressureJournal of Electrocardiology, 2011
- Impaired endothelium mediated vascular reactivity in endogenous Cushing's syndromeEndocrine Journal, 2011
- Influence of respiratory rate on the variability of blood volume pulse characteristicsJournal of Medical Engineering & Technology, 2009
- Use of the pulse transit time trend to relate tidal breathing and central respiratory eventsProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2008
- Bilateral Transit Time Assessment of Upper and Lower Limbs as a Surrogate Ankle Brachial Index MarkerAngiology, 2008
- Factors that Affect Pulse Wave Time Transmission in the Monitoring of Cardiovascular SystemJournal of Clinical Monitoring and Computing, 2008
- Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signalsPhysiological Measurement, 2005