Interventional device tracking under MRI via alternating current controlled inhomogeneities
Open Access
- 23 February 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 346-360
Abstract
Purpose: To introduce alternating current‐controlled, conductive ink‐printed marker that could be implemented with both custom and commercial interventional devices for device tracking under MRI using gradient echo, balanced SSFP, and turbo spin‐echo sequences.Methods: Tracking markers were designed as solenoid coils and printed on heat shrink tubes using conductive ink. These markers were then placed on three MR‐compatible test samples that are typically challenging to visualize during MRI scans. MRI visibility of markers was tested by applying alternating and direct current to the markers, and the effects of applied current parameters (amplitude, frequency) on marker artifacts were tested for three sequences (gradient echo, turbo spin echo, and balanced SSFP) in a gel phantom, using 0.55T and 1.5T MRI scanners. Furthermore, an MR‐compatible current supply circuit was designed, and the performance of the current‐controlled markers was tested in one postmortem animal experiment using the current supply circuit.Results: Direction and parameters of the applied current were determined to provide the highest conspicuity for all three sequences. Marker artifact size was controlled by adjusting the current amplitude, successfully. Visibility of a custom‐designed, 20‐gauge nitinol needle was increased in both in vitro and postmortem animal experiments using the current supply circuit.Conclusion: Current‐controlled conductive ink‐printed markers can be placed on custom or commercial MR‐compatible interventional tools and can provide an easy and effective solution to device tracking under MRI for three sequences by adjusting the applied current parameters with respect to pulse sequence parameters using the current supply circuit.Keywords
This publication has 31 references indexed in Scilit:
- Low‐field MRI: Clinical promise and challengesJournal of Magnetic Resonance Imaging, 2022
- Real‐time MRI guidance of cardiac interventionsJournal of Magnetic Resonance Imaging, 2017
- Steady‐state free precession signals of arbitrary dephasing order and their sensitivity to T2∗Concepts in Magnetic Resonance Part A, 2017
- MRI‐guided vascular access with an active visualization needleJournal of Magnetic Resonance Imaging, 2011
- MR‐guided biopsy: A review of current techniques and applicationsJournal of Magnetic Resonance Imaging, 2008
- Pulse sequences and system interfaces for interventional and real‐time MRIJournal of Magnetic Resonance Imaging, 2008
- Interventional cardiovascular procedures guided by real‐time MR imaging: An interactive interface using multiple slices, adaptive projection modes and live 3D renderingsJournal of Magnetic Resonance Imaging, 2007
- Endovascular interventional MRIJournal of Magnetic Resonance Imaging, 2005
- Is TrueFISP a gradient‐echo or a spin‐echo sequence?Magnetic Resonance in Medicine, 2003
- RF safety of wires in interventional MRI: Using a safety indexMagnetic Resonance in Medicine, 2001