Comparing adverse events associated with LigaSure and Harmonic devices in head and neck surgery
- 8 December 2023
- journal article
- research article
- Published by Wiley in Head & Neck
- Vol. 46 (2) , 378-385
Abstract
Objective: To characterize adverse events, provide a safety profile, and understand patient outcomes after complications arising from LigaSure and Harmonic use in the head and neck region.Methods: Retrospective analysis of adverse events from the Manufacturer and User Facility Device Experience (MAUDE) between January 2013 and 2023.Results: A total of 158 LigaSure and 159 Harmonic events were extracted. There were significantly more reports of Harmonic device overheating (6.9% vs. 0.6%, p = 0.003) and spontaneous self‐activation (4.4% vs. 0%, p = 0.032). Although intra‐operative and post‐operative complications were similar among both groups, there were significantly more intra‐operative bleeding events for LigaSure as compared to Harmonic (8.2% vs. 0.0%, p = 0.001).Conclusion: Understanding technical complications and adverse events attributable to LigaSure and Harmonic devices enables the development of clinically relevant risk mitigation strategies. Surgeons should avoid improper use by remaining vigilant of device functionality and temperature changes.Keywords
This publication has 16 references indexed in Scilit:
- Ligasure impact™ might reduce blood loss, complications, and re-operation occurrence after abdominoplasty in massive-weight-loss patients: A Comparative StudyScandinavian Journal of Surgery, 2019
- Harmonic versus LigaSure hemostasis technique in thyroid surgery: A meta-analysisBiomedical Reports, 2016
- Sealing vessels up to 7 mm in diameter solely with ultrasonic technologyMedical Devices: Evidence and Research, 2014
- Lateral temperature spread of monopolar, bipolar and ultrasonic instruments for robot‐assisted laparoscopic surgeryBJU International, 2013
- Which Hemostatic Device in Thyroid Surgery? A Network Meta-Analysis of Surgical TechnologiesThyroid®, 2013
- Principles and Safety Measures of Electrosurgery in LaparoscopyJSLS : Journal of the Society of Laparoscopic & Robotic Surgeons, 2012
- Hemostasis in thyroid surgery: Harmonic scalpel versus other techniques—a meta‐analysisOtolaryngology–Head and Neck Surgery, 2010
- Google Scholar revisitedOnline Information Review, 2008
- Safety of Same Day Discharge in Patients Undergoing Sutureless Thyroidectomy: A Comparison of Local and General AnesthesiaThyroid®, 2008
- Comparison of LigaSure Vessel Sealing System, Harmonic Scalpel, and Cold Knife TonsillectomyOtolaryngology–Head and Neck Surgery, 2007