Effects of lighting conditions and accommodation on the three-dimensional position of Visian implantable collamer lens
Open Access
- 4 November 2022
- journal article
- research article
- Published by Springer Nature in Eye and Vision
- Vol. 9 (1) , 1-10
Abstract
Background: To investigate the effects of lighting conditions and accommodation on the three-dimensional position of Visian implantable collamer lens (ICL V4c). Methods: This observational study recruited 62 eyes of 31 myopia patients underwent ICL V4c implantation. Anterior segment optical coherence tomography (AS-OCT) assessed the anterior chamber depth (ACD), ACD-ICL (distance from the corneal endothelium to anterior surface of the ICL V4c), vault (distance between the posterior ICL V4c surface and anterior crystalline lens surface), and crystalline lens tilt under various lighting conditions and accommodation relative to the corneal topographic axis at one year after ICL V4c implantation. Baseline was defined as the scotopic condition, which was also the non-accommodative stimulus condition. The ICL V4c tilt was analyzed using MATLAB. The significance level was set at P < 0.05. Results: The ACD-ICL values were similar under various lighting conditions (P = 0.978) but decreased during accommodation (P < 0.001). The vault was significantly smaller under mesopic and photopic conditions than the baseline (P = 0.044 and P < 0.001, respectively) but remained unchanged during accommodation (P = 0.058). The inferotemporal proportion of ICL V4c (88.7%, 55 eyes) and crystalline lens (74.2%, 46 eyes) tilts were not significantly different (P = 0.063). Crystalline lens under various lighting conditions and accommodation exhibited similar tilts. The vertical tilt of ICL V4c was significantly larger under photopic conditions than the baseline (P = 0.038). The horizontal and total tilts were significantly decreased during accommodation (P = 0.043 and 0.013, respectively). Conclusions: The axial position of ICL V4c in the anterior chamber was stable under various lighting conditions. Lighting conditions and accommodation may influence vertical, horizontal and total tilts of ICL V4c.Keywords
Funding Information
- National Natural Science Foundation of China (81770955)
- Research Project Grant of Shanghai Municipal Health Commission (202040285)
- Shanghai Science and Technology Commission (20410710100)
- Joint research project of new frontier technology in municipal hospitals (SHDC12018103)
- Clinical Research Plan of SHDC (SHDC2020CR1043B)
- Project of Shanghai Xuhui District Science and Technology (2020-015)
This publication has 27 references indexed in Scilit:
- Changes in vaulting of myopic and toric implantable collamer lenses in different lighting conditionsActa Ophthalmologica, 2011
- The Effect of Ageing on In Vivo Human Ciliary Muscle Morphology and ContractilityInvestigative Ophthalmology & Visual Science, 2011
- In Vivo Analysis of Ciliary Muscle Morphologic Changes with Accommodation and Axial AmetropiaInvestigative Ophthalmology & Visual Science, 2010
- Posterior Chamber Phakic Implantable Collamer Lens: Changes in Vault During 1 YearJournal of Refractive Surgery, 2010
- Decentration and tilt of a single-piece aspheric intraocular lens compared with the lens position in young phakic eyesJournal of Cataract & Refractive Surgery, 2009
- Anterior segment changes with age and during accommodation measured with partial coherence interferometryJournal of Cataract & Refractive Surgery, 2007
- Analysis of crystalline lens positionJournal of Cataract & Refractive Surgery, 2006
- Static and dynamic analysis of the anterior segment with optical coherence tomographyJournal of Cataract & Refractive Surgery, 2004
- Effect of accommodation and pupil size on the movement of a posterior chamber lens in the phakic eyeOphthalmology, 2004
- U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopiaOphthalmology, 2003