An assessment of the respective contributions of flow-rate and concentration variations to mass discharge variations at the outlets of two combined catchments during rain events
Authors:
- 23 July 2014
- journal article
- research article
- Published by Taylor & Francis in Urban Water Journal
- Vol. 12 (8) , 653-659
Abstract
This paper presents a method for assessing the respective contributions of the variations of flow-rate and concentration of any pollution parameter to the variations of the mass discharge of the same parameter. This method uses a specially designed decomposition of variance, which gives a priority to the information provided by flow-rates, either directly, or through the correlation between flow-rates and concentrations. To demonstrate the potential interest of this method, data monitored on two catchments in the city of Paris (France) are processed according this method, with turbidity being used as a surrogate for suspended solids concentration. Results show that volumes provide a fairly good evaluation of masses at the scale of whole events. Inside any particular event, concentrations are major contributors to the variations of mass discharge, despite the correlations between flow rate and concentration which may be observed for many rain events.Keywords
This publication has 10 references indexed in Scilit:
- Assessment of the contribution of sewer deposits to suspended solids loads in combined sewer systems during rain eventsEnvironmental Science and Pollution Research, 2013
- Relationship between turbidity and total suspended solids concentration within a combined sewer systemWater Science & Technology, 2011
- CSO management from an operator's perspective: a step-wise action planWater Science & Technology, 2011
- Potential of turbidity monitoring for real time control of pollutant discharge in sewers during rainfall eventsWater Science & Technology, 2009
- Reproducibility and uncertainty of wastewater turbidity measurementsWater Science & Technology, 2008
- Sewer system real-time control supported by the M180 guideline documentUrban Water Journal, 2008
- Suitability of CSO performance indicators for compliance with ambient water quality targetsUrban Water Journal, 2008
- Is combined sewer overflow spill frequency/volume a good indicator of receiving water quality impact?Urban Water, 2002
- Urban stormwater management planning with analytical probabilistic modelsCanadian Journal of Civil Engineering, 2001
- Contribution of different sources to the pollution of wet weather flows in combined sewersWater Research, 2001